LED
Status
Global HDD Activity
LAN 1-4 Activity/Link
(LAN 1-2 for Intel
Server Board
S1200BT)
Chassis Identification
®
Intel
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Service Guide
Table 2. Control Panel LED Functions
Color
Condition
Green
On
Green
Blink
Amber
On
Amber
Blink
Off
Green
Blink
Off
Green
On
®
Green
Blink
Off
Blue
On
Blue
Blink
Off
What It Means
System ready/No alarm.
System ready, but degraded: redundancy lost
such as PS or fan failure; non-critical temp/
voltage threshold; battery failure; or predictive PS
failure.
Critical alarm: Voltage, thermal, or power fault;
CPU missing; insufficient power unit redundancy
resource offset asserted.
Non-Critical failure: Critical temp/voltage
threshold; VDR hot asserted; min number fans
not present or failed.
AC power off: System unplugged.
AC power on: System powered off and in
standby, no prior degraded\non-critical\critical
state.
HDD access.
No access and no fault.
LAN link/no access.
LAN access.
Idle.
Front panel chassis ID button pressed.
Unit selected for identification via software.
No identification.