Page 1
Intel® Server System R1000RP Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel® Server System and install components. If you are not familiar with ESD [ElectroStatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
System Overview Intel® Server System R1000RP Family System Features and Components PCI Slots Server Board Power Supply System Fans Memory Slots Hard Drive Bays Air Duct Front Control Panel * 2.5" Hard Drive Bay system as shown...
General Installation Process The installation instructions in this section are for common components of Intel® Server System R1000RP family. Minimum Hardware Requirements Preparing the System To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Observe normal ESD (Electrostatic Discharge) procedures.
General Installation Process Install the Processor A. Open the Socket Lever B. Open the Load Plate Cautions: Push the lever handle Open the load When removing the protective down plate as shown. cover, DO NOT TOUCH the and away gold socket pins. from the socket to release it.
Note: For additional memory configurations, see the Service Guide on the Intel Server Deployment & Management DVD that accompanied ® your Intel Server System, or go to: ® http://www.intel.com/p/en_US/support/ (post-production) CPU Socket Memory sizing and configuration is supported only for qualified DIMMs approved by...
General Installation Process Install Hard Drives 2.5" Hard Drive Carrier (For system with 2.5" hard drive bay only) Remove the drive carrier by pressing the green latch Install the hard disk drive using the four screws as shown. Make Sure to unlock.
Page 10
General Installation Process Install Hard Drives ...continued 3.5" Hard Drive Carrier (For system with 3.5" Hot Swap hard drive bay only) Remove the drive carrier by pressing the green button and opening Remove the four screws securing the HDD interface bracket and remove the lever.
General Installation Process Install Hard Drives ...continued 3.5" Fixed Hard Drive Remove the screws securing the drive carrier to Insert hard drive into the chassis. the carrier with the bottom-side Slide the carrier away of the drive facing up. from the chassis. Screw Note: Hard drive 0 location...
General Installation Process Install the Air Duct Remove Add-in Card CAUTION: Riser Assembly Place the riser Align the two holes on the air duct with the alignment pins on the chassis and install the air duct into place. assembly Use care to avoid pinching system cables. upside down to Grasp the riser assembly with both hands and pull up to...
Mount the NIC module to the rear panel of the chassis and secure the bracket with two screws. ® Connect the cable to the cable connector on the Intel Dedicated Server Management NIC module. Caution: Care should be used when attaching or removing this cable. Mishandling the cable could cause damage.
General Installation Process Install Intel® RAID Smart Battery (optional) Locate the BBU bracket inside the chassis. Align the tabs on the plastic battery holder with mounting holes on the BBU bracket. Slide the plastic battery holder toward the rear of the system until the tabs engage with the mounting holes in the BBU bracket.
Note: The FRUSDR utility must be run for full platform management functionality. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel Server System ®...
SAS Module Main Power SATA 1 SATA_SGPIO eUSB SSD USB 8/9 SATA 0 IPMB SYS FAN_1 CPU FAN SYS FAN_3 SATA 2 SATA 4 SYS FAN_2 See your Intel Server System R1000RP Service Guide for expanded component and connection information. ®...
Page 17
Reference System Fan Connection FAN 4 FAN 1 FAN 2 FAN 3 Fixed System Fans A complete list of accessories and spares can be found at: http://www.intel.com/p/en_US/support/ (post-production only).
Reference System Cabling Diagram For system with 4 x 3.5” fixed hard drive bay: ® Intel Integrated RAID Module CPU Power 350W PS AUX Power Supply SATA 4 SATA 3 Main Power SAS Module SATA 1 SATA 2 SYS FAN_1...
Page 19
Reference System Cabling Diagram For system with 4 x 3.5” hot swap hard drive bay: ® Intel Integrated RAID Module CPU Power PS AUX 350W Power Supply SATA 4 SATA 3 Main Power HSBP_I SAS Module SATA 1 SATA 2...
Page 20
Reference System Cabling Diagram For system with 8 x 2.5” hot swap hard drive bay: ® Intel Integrated RAID Module CPU Power PS AUX 450W Power Supply HSBP_I Main Power SAS Module SYS FAN_1 SYS FAN_2 SYS FAN_3 SATA 0...
Page 23
Intel® Server System R1000RP Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel® Server System and install components. If you are not familiar with ESD [ElectroStatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
System Overview Intel® Server System R1000RP Family System Features and Components PCI Slots Server Board Power Supply System Fans Memory Slots Hard Drive Bays Air Duct Front Control Panel * 2.5" Hard Drive Bay system as shown...
General Installation Process The installation instructions in this section are for common components of Intel® Server System R1000RP family. Minimum Hardware Requirements Preparing the System To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Observe normal ESD (Electrostatic Discharge) procedures.
General Installation Process Install the Processor A. Open the Socket Lever B. Open the Load Plate Cautions: Push the lever handle Open the load When removing the protective down plate as shown. cover, DO NOT TOUCH the and away gold socket pins. from the socket to release it.
Note: For additional memory configurations, see the Service Guide on the Intel Server Deployment & Management DVD that accompanied ® your Intel Server System, or go to: ® http://www.intel.com/p/en_US/support/ (post-production) CPU Socket Memory sizing and configuration is supported only for qualified DIMMs approved by...
General Installation Process Install Hard Drives 2.5" Hard Drive Carrier (For system with 2.5" hard drive bay only) Remove the drive carrier by pressing the green latch Install the hard disk drive using the four screws as shown. Make Sure to unlock.
Page 32
General Installation Process Install Hard Drives ...continued 3.5" Hard Drive Carrier (For system with 3.5" Hot Swap hard drive bay only) Remove the drive carrier by pressing the green button and opening Remove the four screws securing the HDD interface bracket and remove the lever.
General Installation Process Install Hard Drives ...continued 3.5" Fixed Hard Drive Remove the screws securing the drive carrier to Insert hard drive into the chassis. the carrier with the bottom-side Slide the carrier away of the drive facing up. from the chassis. Screw Note: Hard drive 0 location...
General Installation Process Install the Air Duct Remove Add-in Card CAUTION: Riser Assembly Place the riser Align the two holes on the air duct with the alignment pins on the chassis and install the air duct into place. assembly Use care to avoid pinching system cables. upside down to Grasp the riser assembly with both hands and pull up to...
Mount the NIC module to the rear panel of the chassis and secure the bracket with two screws. ® Connect the cable to the cable connector on the Intel Dedicated Server Management NIC module. Caution: Care should be used when attaching or removing this cable. Mishandling the cable could cause damage.
General Installation Process Install Intel® RAID Smart Battery (optional) Locate the BBU bracket inside the chassis. Align the tabs on the plastic battery holder with mounting holes on the BBU bracket. Slide the plastic battery holder toward the rear of the system until the tabs engage with the mounting holes in the BBU bracket.
Note: The FRUSDR utility must be run for full platform management functionality. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel Server System ®...
SAS Module Main Power SATA 1 SATA_SGPIO eUSB SSD USB 8/9 SATA 0 IPMB SYS FAN_1 CPU FAN SYS FAN_3 SATA 2 SATA 4 SYS FAN_2 See your Intel Server System R1000RP Service Guide for expanded component and connection information. ®...
Page 39
Reference System Fan Connection FAN 4 FAN 1 FAN 2 FAN 3 Fixed System Fans A complete list of accessories and spares can be found at: http://www.intel.com/p/en_US/support/ (post-production only).
Page 40
Reference System Cabling Diagram For system with 4 x 3.5” fixed hard drive bay: ® Intel Integrated RAID Module CPU Power 350W PS AUX Power Supply SATA 4 SATA 3 Main Power SAS Module SATA 1 SATA 2 SYS FAN_1...
Page 41
Reference System Cabling Diagram For system with 4 x 3.5” hot swap hard drive bay: ® Intel Integrated RAID Module CPU Power PS AUX 350W Power Supply SATA 4 SATA 3 Main Power HSBP_I SAS Module SATA 1 SATA 2...
Page 42
Reference System Cabling Diagram For system with 8 x 2.5” hot swap hard drive bay: ® Intel Integrated RAID Module CPU Power PS AUX 450W Power Supply HSBP_I Main Power SAS Module SYS FAN_1 SYS FAN_2 SYS FAN_3 SATA 0...