Rear view of the Control Panel:
Flexible supply cable
Connector
Protective box for electrical assembly
If the cardan telescopic shafts are too
short, extensions can be added (not provi-
ded, but available as an accessory).
These are added by pressing, and they
are fixed by the cover that is included.
Gas conversion
Model VT Dual. 1
Important!
Any alteration that is to be made to the
appliance to convert it to a different
type of gas should only be carried out
by a qualified technician.
Information for Technical Assis-
tance: whenever the type of gas or the
appliance's pressure is changed, the new
regulation plate should be placed on top of
the old one so that the new features can
be seen after the change.
The tasks involved in conversion are:
* Replace the injectors.
* Adjust the taps' minimums.
The injectors required for each gas type
are shown in table 1.
To replace the injectors, follow these ins-
tructions:
1 Remove the grids and upper parts of the
burner so that the injector can be seen.
fig. 6
2 Using a number 7 pipe spanner, remove
the injectors and replace them with the
new ones. Take care to press the injector
down firmly so that there is no leakage.
3 Replace the grid and burners that were
previously removed.
When the injectors have been changed,
this is how to adjust the minimums:
1 Take the oven or the control panel out so
that you can access the gas taps.
2 Turn the burners on to their minimum.
3 Use a slim, grooved screwdriver to turn
the screw located to the right or in the
centre of the gas tap's shaft (the flame
increases when you turn to the left and
decreases when you turn to the right).
4 When properly adjusted, check that the
flame does not go out when you turn the
knob quickly from maximum to minimum.
TEKA INDUSTRIAL, S.A. assumes no
responsibility for any hob malfunction if the
gas conversion or the adjustment of the
burners' minimums has not been carried
out by TEKA's official personnel.
Table 1
Burner
Rapid
Semi-rapid
Ø injector expressed in 1/100 mm.
Family
Second
Group H
Group E+
116
116
97
97
GB
Third
Group 3+
85
66
19

Hide quick links: