Special Condition for Safe Use (X):
1. The equipment with the Transient Protection (T1) option is not capable of withstanding
the 500 V insulation test required by Clause 6.5.1 of EN60079-15:2010. This must be
taken into account when installing the equipment.
ND ATEX Dust Ignition-proof
Certificate: KEMA02ATEX2231X
Standards: EN60079-0:2006, EN60079-26:2007, EN61241-0:2006
Markings:
Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm. Installation, maintenance, and use shall take
into account the environmental conditions to which the diaphragm will be subjected.
The manufacturer's instructions for installation and maintenance shall be followed in
detail to assure safety during its expected lifetime.
2. The Rosemount 4600 Transmitter is provided with a permanently connected
unterminated cable. The free end of the cable shall be connected using a suitable
junction box, e.g. in type of protection flameproof enclosure "d" or increased safety "e".
Brazil
E2 INMETRO Flameproof
Certificate: UL-BR 15.0509X
Standards: ABNT NBR IEC 60079-0: ABNT NBR IEC 60079-1:
Markings: Ex d IIC Ga/Gb, T6(–60 °C ≤ T
Special Condition for Safe Use (X):
1. This device contains a thin wall diaphragm. Installation, maintenance and use shall take
into account the environmental conditions to which the diaphragm will be subjected.
The manufacturer's instructions for installation and maintenance shall be followed in
detail in order to assure safety during its expected lifetime.
Technical Regulations Customs Union (EAC)
EM EAC Flameproof
Certificate: RU C-US.GB05.B.00401
Markings: Ga/Gb Ex d IIC T6...T4 X, T6(–60 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate for special conditions.
IM EAC Intrinsically Safe
Certificate: RU C-US.GB05.B.00401
Markings: 0Ex ia IIC T4 Ga X (–40 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Combinations
K1 Combination of E1, I1, and N1
K5 Combination of E5 and I5
K6 Combination of E6 and I6
KA Combination of E1, I1, E6, and I6
KB Combination of E5, E6, I5, and I6
KC Combination of E1, E5, I1, and I5
KM Combination of EM and IM
12
II 1 tD A20 T85 °C (–40 °C ≤ T
ABNT NBR IEC 60079-26.
≤ +70 °C)
a
≤ +70 °C), T5/T4(–60 °C ≤ T
a
≤ +70 °C), T4/T5(–60 °C ≤ T
a
≤ +70 °C)
a
September 2016
≤ +80 °C)
a
≤ +80 °C)