Download Print this page

Emerson Rosemount 4600 Quick Start Manual page 11

Oil & gas panel pressure transmitter
Hide thumbs Also See for Rosemount 4600:

Advertisement

September 2016
I6 Canada Intrinsic Safety
Certificate: 1384913
Standards: CSA Std C22.2 No. 25-1966; CSA Std C22.2 No. 30-M1986;
Markings: Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D;
Europe
E1 ATEX Flameproof
Certificate: KEMA02ATEX2231X
Standards: EN60079-0:2006; EN60079-1:2007; EN60079-26:2007;
Markings:
Special Condition for Safe Use (X):
1. This device contains a thin wall diaphragm. installation, maintenance, and use shall take
into account the environmental conditions to which the diaphragm will be subjected.
The manufacturer's instructions for installation and maintenance shall be followed in
detail to assure safety during its expected lifetime.
2. The model 4600 pressure transmitter is provided with a permanently connected
unterminated cable. The free end of the cable shall be connected using a suitable
junction box, e.g. in type of protection flameproof enclosure "d" or increased safety "e".
I1 ATEX Intrinsic Safety
Certificate: Baseefa03ATEX0114X
Standards: EN60079-0: 2012+A11:3013, EN60079-11:2012
Markings:
Table 2. Input Parameters
Parameters
Voltage U
Current I
Power P
Capacitance C
Inductance L
Special Condition for Safe Use (X):
1. The equipment with the Transient Protection (T1) option is not capable of withstanding
the 500 V insulation test required by Clause 6.3.13 of EN60079-11:2012. This must be
taken into account when installing the equipment.
N1 ATEX Type n
Certificate: Baseefa03ATEX0115X
Standards: EN60079-0:2012+A11:2013, EN60079-15:2010
Markings:
CAN/CSA-C22.2 No. 94-M91; CSA Std C22.2 No. 142-M1987;
CAN/CSA-C22.2 No. 157-92; CSA Std C22.2 No. 213-M1987;
CAN/CSA-E79- 0-95; CAN/CSA- E79-1-95; CAN/CSA- E79-11-95;
ANSI/ISA No. 12.27.01-2011
Temperature Code T3C (–50 °C to 70 °C); Intrinsically Safe for use in Class I,
Zone 0 Ex ia IIC T4 (–50 °C to 70 °C) when connected in accordance with
Rosemount drawing 04620-5005; Enclosure Type 4X; For entity parameters
see control drawing 04620-5005
II 1/2 G Ex d IIC T6 (–40 °C ≤ T
II 1 G Ex ia IIC T4 Ga (–40 °C ≤ T
HART
30 V
i
200 mA
i
1.0 W
i
35 nF
i
390 μH
i
II 3G Ex nA IIC T5 Gc (–40 °C ≤ T
U
= 42.4V
i
≤ +70 °C)
a
≤ +70 °C)
a
≤ +70 °C)
a
Quick Start Guide
11

Advertisement