5.9
Testing the water points electrically
Requirement:
►
Side panel on right removed.
5.9.1
Measure water points motor (simple measurement)
1.
Disconnect plug X2 from power module and measure resistance
on the wires for the water points motor, contact 3 and 4.
If the resistance value is ∞, check wires for interruptions and measure
directly on the water points motor.
Technical specifications EU:
Nominal voltage:
230–240 V
Power input:
7 W / 4W
Frequency:
50/60 Hz
6,0 kΩ ± 800 Ω
Resistance:
or
4,6 kΩ ± 800 Ω
Depending on
manufacturer
Speed:
4-5 min
Technical specifications TC / USA:
Nominal voltage:
120 V
Power input:
5 W
Frequency:
50 / 60 Hz
5,9 kΩ ± 800 Ω
Resistance:
Or
4,7 kΩ ± 800 Ω
Depending on
manufacturer
Speed:
5/6 min
-1
-1