5.3

Testing dispenser electrically

Requirement:
Outer door removed.
5.3.1
Measuring the coil
5.
Disconnect plug-and-socket connection.
Measure resistance on the coil.
Technical specifications EU:
Pulse voltage of coil:
Frequency:
Resistance:
Rinse aid capacity:
Rinse aid amount at setting 1–6
Technical specificationsUSA:
Pulse voltage of coil:
Resistance:
Rinse aid capacity:
Rinse aid amount at setting 1–6
Technical specifications EA (East Asia):
Pulse voltage of coil:
Resistance:
Rinse aid capacity:
Rinse aid amount at setting 1–6
Technical specifications TC:
Pulse voltage of coil:
Resistance:
Rinse aid capacity:
Rinse aid amount at setting 1–6
320 V
DC
11 kΩ ± 1 kΩ
80 ml
1 ml per setting
165 V DC
2,67 kΩ ± 210 Ω
80 ml
1 ml per setting
280 V DC
8,4 kΩ ± 800 Ω
80 ml
1 ml per setting
155 V DC
2,67 kΩ ± 210 Ω
80 ml
1 ml per setting