Replacing the regeneration valve
Requirement:
√ Side panel on left removed.
√ Optionally: Heat exchanger emptied.
√ Water drained from the salt dispenser.
5.27.1 Removal
1.
Rotate valve anti-clockwise.
2.
Pull out valve forwards.
5.27.2 Remove anchor
1.
Insert a small screwdriver in the valve position
2.
Lever the valve insert carefully loosely
3.
Remove the valve insert from the regeneration unit
Install in reverse sequence.