5.2
Testing/replacing the door sensor
Requirement:
►
Outer door removed.
►
Fascia removed.
►
Right side panel removed.
5.2.1
Measuring the voltage
►
Very carefully remove the plug from the door sensor. Do not pull
on the wires.
►
Measure voltage on both contact of the power cord.
►
If 13.5 V DC is supplied to door sensor, the power module and the
connection cable works properly -> replace door sensor.
►
If this voltage is not applied, measure the voltage on the power
module.
►
No voltage -> replace power module.
►
Voltage available -> measure resistance of the connection cables
between power module and the connections of the component.
Rectify interruption.
Measure voltage on the module
►
When the plug is connected, the supply voltage can
be measured from the front on the two yellow wires
on the power module. When the plug is removed,
the main switch is inoperative.
5.2.2
Removal
3.
Door sensor.
4.
Loosen the two Torx 10 screw on the side of the door closure
recess.
Panel of door closure recess
►
The panel of the door closure recess may become
detached when the door sensor is removed. Hold
firmly.
5.2.3
Installation
Installation is in reverse sequence.
The plugs are coded.