3.7

Water inlet

When a rinse programme starts, the water inlet valve is actuated for
5 seconds. Water is expected to run in. Simultaneously pulses are
expected from the impeller wheel counter on the electronics. If these
remain off, an error code is displayed and the programme is not
started.
If pulses are received, the programme is started.
When the programme starts, the electronic control opens the Aqua-
stop/water inlet valve (filling valve).
Water flows into the water inlet via the supply hose. The flow sensor
and the free flow line are located in the supply channel of the water
inlet.
The water flows either into the granulate container (soften) or into the
salt container (regenerate) via the regeneration valve in the water
softening system.
The outlet opening of the water softening system conveys the water
back to the water inlet.
The water flows directly into the rinsing tank via the outlet opening.
1
Free flow line
2
Outlet opening
3
Water softening system
4
Regeneration valve
5
Water inlet valve
6
Impeller wheel with flow sensor
7
Expansion opening
8
Supply hose
9
Drainage hose ventilation valve