5.39
Replacing the drain pump
Requirement:
√ Base panel and plate removed.
√ Water drained.
5.39.1 Removal
1.
Remove plug.
2.
Pull catch mechanism lever (1) for the drain pump forwards.
3.
Rotate drain pump clockwise.
4.
Remove pump forwards out of the pump sump.
5.39.2 Installation
►
Proceed in reverse sequence.