Testing Aquastop Valve Electrically - Jenn-Air JDB9600AW Technical Education

Flush-mount dishwasher for european cabinets
Table of Contents

Advertisement

5.6

Testing Aquastop valve electrically

1.
Loosing locking lever
2.
Fold the Cover with the inlet hose outward.
Technical specifications EU:
Nominal voltage:
220 ~ 240 V
Frequency:
50/60 Hz
Resistance:
4.2 kΩ ± 1 KΩ
Technical specifications TC / USA:
Nominal voltage:
110 ~ 127 V
Frequency:
60 Hz
990 Ω ± 50 Ω
Resistance:
1.
Disconnect plug-and-socket connection and measure the
resistance.