Metabo DW 125 Original Instructions Manual page 14

Hide thumbs Also See for DW 125:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
en
ENGLISH
Original instructions
1. Declaration of Conformity
Under our sole responsibility, we hereby declare
that these compressed air angle grinders, identified
by type and serial number *1), meet all relevant
requirements of directives *2) and standards *3).
Technical documents for *4) - see Page 3.
2. Specified Use
The air tool, when fitted with original Metabo acces-
sories, is suitable for grinding and abrasive cutting
of metal, concrete, stone and similar materials
without the use of water.
It is not suitable for polishing, sanding or wire
brushing operations.
The tool must only ever be operated with a com-
pressed air supply. The maximum supply pressure
specified on the air tool must never be exceeded.
The air tool must not be operated using explosive,
inflammable or hazardous gases. It must not be
used as a lever, crushing tool or striking tool.
Any other use does not comply with the intended
purpose. Unspecified use, modification of the air
tool or use of parts that have not been tested and
approved by the manufacturer can cause unfore-
seeable damage.
The user bears sole responsibility for any damage
caused by improper use.
Generally accepted accident prevention regula-
tions and the enclosed safety information must be
observed.
3. General Safety Instructions
For your own protection and for the
protection of your air tool, pay attention to
all parts of the text that are marked with
this symbol!
WARNING – Reading the operating instruc-
tions will reduce the risk of injury.
WARNING Read all safety warnings and
instructions. Failure to follow all safety warn-
ings and instructions may result in electric shock,
fire and/or serious injury.
Keep all safety instructions and information for
future reference.
Pass on your air tool only together with these docu-
ments.
- The user or user's employer must evaluate the
specific risks associated with each application of
the tool.
- The safety instructions must be read and under-
stood before installing, operating, repairing or
maintaining the tool, and also before replacing any
accessory parts or carrying out any work in the
vicinity of the air tool. Failure to read and follow the
instructions may lead to serious injury.
14
- Only qualified, trained operators are authorised to
install, adjust or use the air tool.
- The air tool must not be modified. Any modifica-
tions may reduce the efficiency of the safety
measures and increase risks for the operator.
- Never use air tools that have been damaged. Look
after your air tools carefully. Regularly check that
all moving parts are functioning correctly and do
not jam. Also ensure that no parts are broken or
damaged to an extent that they affect the opera-
tion of the air tool. Check that all signs and labels
are legible and intelligible. Have damaged parts
repaired or replaced before using the device.
Many accidents are caused by poorly maintained
air tools.
4. Special Safety Instructions
4.1
Risks associated with ejected parts
- Disconnect the air tool from the compressed air
supply before replacing the mounted tool or
accessory parts, and also before carrying out
repairs or settings.
- If either the workpiece, accessory parts or the air
tool breaks, parts may be ejected at high speed.
- While operating, maintaining or repairing the air
tool, or replacing accessory parts, you must
always wear impact-resistant safety goggles. The
degree of protection required for each individual
task must be evaluated separately in each case.
- Ensure that the workpiece is securely attached.
- You must ensure that the abrasive is securely
mounted on the grinder for abrasives.
- Check that the maximum operating speed of the
abrasive (calculated in revolutions per minute)
equals or exceeds the rated speed of the spindle.
Furthermore, you must not attach brushes to the
machine if their rotational speed is higher than the
maximum permissible speed for brushes;
- Ensure that the safety guard is fitted, in good
condition and properly secured. It must be
checked regularly.
- Regular checks must be carried out to verify that
the air tool's rotational speed does not exceed the
speed specified on the tool. These speed checks
must be conducted when no mounted tool is fitted.
Metabo's Service Centre can perform these
checks for you.
- Ensure that any sparks or fragments emitted
during operation do not pose a risk.
- Disconnect the air tool from the compressed air
supply before replacing the mounted tool or
accessory parts, and also before carrying out
maintenance, settings or cleaning.
- Check that the clamping flanges comply with the
manufacturer's instructions. Also check that they
are in good condition, for example, that they are
even and do not have cracks;
- You must check whether the spindle and spindle
thread are damaged or worn.