Page 1
Hot Spot Wireless Subscriber Gateway WSG-401 User’s Manual...
Page 2
PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice.
Internet access for wired, and wireless subscribers. Internet subscriber gateway WSG-401 combines all the functionalities in a single, tiny box, WSG-401 can work independently, no enormous RADIUS system integration, and no much computer expertise required, this benefit customer to deploy their Hot Spot business faster and easier than ever.
Page 5
Web-based Accounting, and proprietary billing mechanism, which can help you prepare a billing mechanism in a very short time, and billing system in WSG-401 works without RADIUS system, and bring most convenience, the least efforts for billing applications. l Exclusive Printer Accounting Machine operators may customize the printout information for different billing application.
1.3 WSG-401 Outlook Figure 1-1 WSG-401 Outlook 1-3-1 Top Panel The top panel of the WSG-401 is shown below. Figure 1-2 WSG-401 Top Panel WSG-401 User Manual...
Page 7
Used to connect the external power supply with PLANET WSG-401 device. 2. LAN Port: WSG-401 supports four auto-sensing RJ-45 ports and all ports can be auto-switched to MDI-II connections. The LAN ports used for linking hosts or other networking device.
1. Reset Button: WSG-401 integrates a reset button at the left side panel of the device. Under some circumstances you might need to reset the device. Figure 1-4 WSG-401 Left Side Panel 1.4 Technical Specifications 1-4-1 Hardware Specifications Network Specification IEE802.3 10BaseT Ethernet...
Page 9
Input: 100-240 VAC, 50/60 Hz Output: 5V, min 1.4A LED Indicators One POWER LED One WAN Link/Activity LED Four LAN Link/Activity LEDs One Wireless Link/Activity LED One Status LED Dimension Size: 200(L) x 130(W) x 44(H) mm Weight: About 400g (Net) WSG-401 User Manual...
Page 10
PPPoE WAN Client • PPTP WAN Client • • IP Routing • NTP (Network Time Protocol) Support • IP Multicast support Marketing Cooperation • Advertisement URL link • Walled garden • Customize Login Page • Portal Page WSG-401 User Manual...
Page 11
Scheduled Firmware Upgrade • Backup/Restore/Factory Default Setting • LAN Device Management • Dynamic DNS • System Information Table • Real-time Current User List / DHCP Clients List / Session List / Account List • Syslog • Status Report (Daily/Monthly/System/Network) WSG-401 User Manual...
2. Hang WSG-401 on the wall by sliding the two screws in the mounting brackets. Note: If the screws are not properly anchored, the strain of the cables connected to the WSG-401 rear panel connectors could pull out the WSG-401 from the wall.
2.3 Installation Requirements Before installing the WSG-401, make sure your network meets the following requirements. System Requirements The WSG-401 requires one of the following types of software: l Windows 98 Second Edition/NT/2000/XP l Red Hat Linux 7.3 or later version l MAC OS X 10.2.4 or later version...
1. Place the WSG-401 and Mini account generator printer on a flat work surface. 2. Connect the DB25 connector of printer cable into the device port on the rear of the WSG-401. 3. Plug the other end of the printer cable into the RJ11 port of the mini account generator printer. Check that the account generator printer status LED lights.
Page 15
Status LED lights. 7. Configure the further parameters via a web browser. Figure 2-1 WSG-401 Connection WSG-401 User Manual...
Step 1: Start your browser, and then enter the factory default IP address 192.168.0.1 in your browser’s location box. Press Enter. Step 2: The WSG-401 configuration tools menu will appear. In the Username and Password field, type the factory default user name (admin) and password (password) and click “Getting Started”.
Page 17
F Username and Password can consist of up to 20 alphanumeric characters and are case sensitive. F If for some reason your password is lost or you cannot gain access to the WSG-401 Configuration Program, please press the reset button to load the device to manufacturer defaults.
Page 18
Empty Enter the secondary DNS server IP address for the xDSL/Cable Server connection (provided by your ISP). If the primary DNS Server IP were not available, meanwhile, Secondary DNS Server IP would start in the same time. WSG-401 User Manual...
Page 19
PPP MTU Setting 1492 MTU (Maximum Transfer Unit) specifies maximum transmission unit size. TCP MSS Setting 1452 MSS (Maximum Segment Size) specifies maximum segment size. Service name Empty Your ISP will provide the service name. WSG-401 User Manual...
Page 20
Connect on Demand and Max Idle Time Connect on Demand Enable You can configure your WSG-401 to cut your connection with your ISP after a specified period of time (Max Idle Time). If you have been disconnected due to inactivity,...
Page 21
My Subnet Mask Empty by your ISP. Enter the PPTP server Gateway IP address provided by Gateway IP Address Empty your ISP. PPTP Server IP Empty Enter the PPTP server IP address provided by your ISP. Address WSG-401 User Manual...
Page 22
Connect on Demand and Max Idle Time Connect on Demand Enable You can configure your WSG-401 to cut your connection with your ISP after a specified period of time (Max Idle Time). If you have been disconnected due to inactivity,...
Page 23
Disables or set the use of the WEP algorithm. Enabling the security can protect your data while it is transferred from one station to another. The WSG-401 supports 64-bit, 128 bit or 256 bit WEP encryption. Enter 5 characters for ASCII 64-bit WEP Key.
Page 24
Step 5: E-mail Server Setting WSG-401 allows an extra Email server parameter to forward the subscriber’s E-mail. Figure 3-7 E-mail Service Setting Screen Description Item Default Email Server Redirect Disables or enables email server redirect function. To prevent some subscriber’s original Email server may protect by firewall or NAT network.
Page 25
Internet service without any extra authentication software. If “Built-in Authentication” is selected, service provider can generate the subscriber account inside WSG-401, and the system will authenticate the subscriber login according to the generated account.
Page 26
Time to Finish― The subscriber can access Internet only one time with one account. Once subscriber login, the pre-defined usage time will start until run out even the subscriber stop to access the Internet before run out. WSG-401 User Manual...
Page 27
There are two different choices, one is exclusive printer (Account Generator Printer), and the other is non-exclusive printer. Exclusive printer is a portable thermal printer that is integrated with WSG-401 to press button to generate accounts and receipt immediately without PC operating. Non-exclusive printer can use the PC Web-based browser to print out user account.
Page 28
Figure 3-10 Printer Setting Button B Button A Button C Figure 3-11 Account Generator WSG-ACG WSG-401 User Manual...
Page 29
This function allows you to produce custom bill based on your requirements. Click “I want to setup the web-based accounting now if exclusive printer cannot work” to open the “Web-based Account Generator Setting” screen to start the web-based accounting function. WSG-401 User Manual...
Page 30
This function allows you to produce custom bill based on your requirements. Web-based Account Username account Enter the user name for web-based account generator. The user name can consist of up to 80 alphanumeric characters and is case sensitive. WSG-401 User Manual...
Page 31
Confirm Empty Enter the password for confirmation. Click on button to preview and operate account generator panel. Button A Button B Button C Figure 3-14 Account Generator Panel Click on button to add a new account. WSG-401 User Manual...
Page 32
Figure 3-15 Example-Account Printout WSG-401 User Manual...
Page 33
Select the check boxes and click ‘Delete’ to delete accounts. Delete all accounts in account list. Note: This page will refresh automatically every 5 minutes. If you would like to leave the account generator panel, please click Logout to exit. WSG-401 User Manual...
Page 34
Customize Printout Text This function allows you to produce custom bill based on your requirements. Figure 3-17 Customize Printout Text Setting Screen Click the button to displays the account on the screen as it would appear when printed. WSG-401 User Manual...
Page 36
Figure 3-20 Example-Post-paid Printout WSG-401 User Manual...
Page 37
This function allows remote user to management the Administrator IP device. You can specify one or any IP addresses for Address remote control the system. Click the button to save the settings then the system will restart. WSG-401 User Manual...
13. Portal Page 14. Advertisement 15. Walled Garden 16. DDNS 17. LAN Devices 18. Syslog 19. Wireless Figure 3-22 Advanced Setting Item Screen Note: After change the settings of device, please click apply button to save the new settings. WSG-401 User Manual...
Page 39
3-2-1 System Define the WSG-401 System configuration. Figure 3-23 System Setting Screen WSG-401 User Manual...
Page 40
Empty alphanumeric characters. Location Information Empty Enter your location information. Date/Time System The system date of the WSG-401. The valid setting of Date (Year/Month/Day) Date year is from 2002 to 2035. System Time (Hour:Minute:Second) The system time of the WSG-401.
Page 41
Disable specific recipients at same time. This function allows remote user to ping the Allow remote user to ping the WSG-401 through Internet. Ping is normally used to Enable device test the physical connection between two devices, to ensure that everything is working correctly.
Page 42
Figure 3-26 Restart Dialog Box l Device IP (LAN IP) Setting Figure 3-27 Device IP (LAN IP) Setting Item Default Description IP Address 192.168.0.1 Internal LAN IP address of your WSG-401. Subnet Mask 255.255.255.0 Subnet mask of your WSG-401. WSG-401 User Manual...
Page 43
Figure 3-30 DHCP Client Setting Screen Static IP Figure 3-31 Static IP Setting Screen Item Description IP Address Enter the IP address for the xDSL/Cable connection (provided by your ISP). Subnet Mask Enter the subnet mask provided by your ISP. WSG-401 User Manual...
Page 44
80 alphanumeric characters and is case sensitive. PPP MTU Setting 1492 MTU (Maximum Transfer Unit) specifies maximum transmission unit size. TCP MSS Setting 1452 MSS (Maximum Segment Size) specifies maximum segment size. Service Name Empty Your ISP will provide the service name. (Option) WSG-401 User Manual...
Page 45
Default Description Connect on Demand and Max Idle Time Connect on Demand Enable You can configure your WSG-401 to cut your connection with your ISP after a specified period of time (Max Idle Max Idle Time 10 Minutes Time). If you have been disconnected due to inactivity,...
Page 46
Connection ID or connection name. Connect on Demand and Max Idle Time Connect on Demand Enable You can configure your WSG-401 to cut your connection with your ISP after a specified period of Max Idle Time 10 Minutes time (Max Idle Time). If you have been disconnected...
Page 47
Enter the Web server port number. The Web server port allowed range is 80 or 8010 to 8060. For access the Web Server Port WSG-401 system under NAT, please “http://WAN Port IP Address: Port Number”. SSL Security Disable Enables or disables the SSL security. WSG-401 User Manual...
Page 48
DHCP Server IP Address Empty Enter the IP address of DHCP server. The WSG-401's DHCP server is turned on and running by default DHCP Server when you install it in your network. DHCP Pool Starting 192.168.0.2 Enter the DHCP Pool Starting IP address.
Page 49
25 or 2500 to 2599. Click Apply button to save the new settings. WSG-401 User Manual...
Page 50
Internet service without any extra authentication software. If “Built-in Authentication” is selected, service provider can generate the subscriber account inside WSG-401, and the system will authenticate the subscriber login according to the generated account.
Page 51
3-2-5 Billing The function is used to setup a billing profile. A billing profile is a description of how you want to charge your customer. Figure 3-36 Billing Setting Screen WSG-401 User Manual...
Page 52
Enable Credit Card Service Disable Enables or disables the credit card service. Before you enable credit card service, make sure that your credit service is configured to work. For details, see section 3-2-6 Credit Service. Figure 3-38 Credit Service Setting Screen WSG-401 User Manual...
Page 53
5 minutes, it means if the account doesn’t send packet in 5 minutes, the account will logout automatically. Accumulation Time to Finish login login logout login logout login Time Bar Time Bar finish logout Usage time= A Usage time= A+B+C Figure 3-40 Accumulation and Time to Finish WSG-401 User Manual...
Page 54
Account Usage time The duration of the billing period. When this period expires, user account will be discontinued. Charge Enter the unit rate amount (i.e. 35.00) that most of your accounts are charged for one day of service. WSG-401 User Manual...
Page 55
Figure 3-41 Post-paid Procedure Diagram Click Apply button to save the new settings. Click Apply button, the success dialog box appears. Click on Back to return to Billing setting screen. Figure 3-42 Success Dialog Box WSG-401 User Manual...
Page 56
3-2-6 Accounting This function allow service provider to generate the subscriber accounts. Figure 3-43 Accounting Setting Screen WSG-401 User Manual...
Page 57
The system allows you to print all your bills. Enter the print number of copies. Can be replenished by Enable Click the check box to enable the replenish function. subscriber Figure 3-44 Account Process Diagram Can be replenished by subscriber=Enable WSG-401 User Manual...
Page 58
Define each button’s billing profile. Select one billing profile by clicking in the list box. Print to… Account Generator Select printer to print out your account. Printer Click on button to preview and operate account generator panel. Figure 3-46 Web-based Account Generator Panel WSG-401 User Manual...
Page 60
A, and 3 times is button A x 3, which is same as now. Discount Price Plan Disable Enables or disables the discount price plan. based on “Button Presses” Note: Before configuring the one-button printer accounting, you have to setting the billing profile of web-based account generator panel. WSG-401 User Manual...
Page 61
Plan based on “Button the base charge and select enable to active the Disable Presses” discount price plan. Note: Before configuring the one-button printer accounting, you have to setting the billing profile of web-based account generator panel. WSG-401 User Manual...
Page 62
Unit Price Enter the amount of charge level. Click Apply button to save the new settings. Click Apply button, the success dialog box appears. Click on Back to return to Accounting setting screen. Figure 3-51 Success Dialog Box WSG-401 User Manual...
Page 63
3-2-7 Credit Card WSG-401 provides two credit card services (“Authorize.net” and “iTable”) that allow service provider to authorize, process, and manage credit transactions directly from Internet. Figure 3-52 Credit Card Setting Screen Item Default Description Authorize.net Merchant ID Empty Enter your Merchant ID. This is a Merchant Identification Number that you’re received from your Merchant Provider.
Page 64
Click Apply button, the success dialog box appears. Click on Back to return to Accounting setting screen. Figure 3-53 Success Dialog Box Please follow steps below to pay using credit card. Step 1: Choose Credit Card service on the login page. Click Figure 3-54 Login Page WSG-401 User Manual...
Page 65
Credit card expiration date Empty Enter the credit card expiration date. The allowed format is MM/YY. Enter Email Address Empty Enter your email address. The system will e-mail you account information once your payment information has been successfully authorized. WSG-401 User Manual...
Page 66
Step 3: After valid payment information has been provided, the subscriber will obtain one valid account to login or the Figure 3-67 screen will appear. Figure 3-56 User Account Information Figure 3-57 WSG-401 User Manual...
Page 67
3-2-8 Keypad Figure 3-58 Keypad Setting Screen Note: This function only support three-button printer WSG-401 User Manual...
Page 68
Enter the amount of charge level. Please follow steps below to create accounts using keypad function. l Use for Pre-Paid Billing Step 1: Click the Billing in the Advanced Setup menu, select enable Pre-Paid, click Apply. Figure 3-59 Billing Setting Screen WSG-401 User Manual...
Page 69
Step 3: You can use keypad to create subscriber accounts now. Press keypad hot key and then press Enter. A new subscriber account is generated, and the account information should be printed. Figure 3-61 Step 4: Subscriber can use this account to access Internet now. WSG-401 User Manual...
Page 70
Step 1: Click the Billing in the Advanced Setup menu, select enable Post-paid, click Apply. Figure 3-62 Billing Setting Screen Step 2: Click the Keypad in Advanced Setup Menu, Define the billing plan of post-paid, click Apply. Figure 3-63 Keypad Hot Key Setting Screen WSG-401 User Manual...
Page 71
This account information is including serial number, username, password and account create time. Figure 3-64 Step 4: When subscriber wants to terminate the Internet service, press *, serial number and then press Enter, a bill should be printed. Figure 3-65 WSG-401 User Manual...
Page 72
WSG-ACG operations Enter the date (MonthDate) PS/2 Keypad Figure 3-66 Keypad Hot Key List l Daily Account Report Printout Press ABCAA Figure 3-67 Daily Account WSG-401 User Manual...
Page 73
Monthly Account Report Printout Press ABCBB Figure 3-68 Monthly Account l System Status Report Printout Press ABCCC Figure 3-69 System Status Report Printout WSG-401 User Manual...
Page 74
PC-connected printer. Figure 3-71 Logo Setting Screen Item Description File Path Enter the file pathname of the logo file in the File Path field. Click Apply button to save the new settings. WSG-401 User Manual...
Page 75
This function helps them to realize the ideal. The page elements are including welcome image, background color, article etc. Certainly the administrator can decide to use only standard form. The WSG-401 provides three different login page formats, including standard, redirect, advanced and frame format.
Page 76
The allowed format is Hexadecimal. Figure 3-74 Login Page Screen Redirect This allow service provider to redirect the subscriber’s browser to a specified home page. Figure 3-75 Redirect Login Page Setting Screen WSG-401 User Manual...
Page 77
Copy and paste the following HTML Code into your home page to produce redirect subscriber login page. Figure 3-76 Redirect Login Page Code Screen WSG-401 User Manual...
Page 78
Advanced This function allow user to design login page of WSG-401. Figure 3-77 Advanced Login Page Setting Screen Item Default Description Welcome Slogan Welcome The maximum allowed characters length is 80. Page Background None The page background can be none or specified color. For the background color format please views the color grid.
Page 79
This function allow service provider can decide whether they want an “Information Window” pop-up on subscriber PC when authenticate successful or not and specified text of information window. Subscriber can type “http://1.1.1.1/info” to open the information window again or enter “http://1.1.1.1/logout” to logout immediately if accumulation billing selected. WSG-401 User Manual...
Page 80
Figure 3-80 Example-Login Page Screen Figure 3-81 Example-Login Page Screen Figure 3-82 Information Window WSG-401 User Manual...
Page 81
Billing Type=Time to Finish Can be replenished by subscriber=Disable Figure 3-83 Information Window Billing Type=Time to Finish Can be replenished by subscriber=Enable WSG-401 User Manual...
Page 82
Figure 3-84 Information Window Billing Type=Accumulation Can be replenished by subscriber=Disable Figure 3-85 Information Window Billing Type=Accumulation Can be replenished by subscriber=Enable Figure 3-86Logout Successfully Dialog Box Billing Type=Accumulation WSG-401 User Manual...
Account Printout This function allow service provider to specified text of account printout. Figure 3-89 Account Printout Customization Setting Screen Click Apply button to save the new settings. WSG-401 User Manual...
Page 85
Click Apply button, the success dialog box appears. Click on Back to return to Account Printout Customization setting screen. Figure 3-90 Success Dialog Box WSG-401 User Manual...
Credit Card Standard Login Page This function allow service provider to customize the additional credit card message for the standard login page. Figure 3-93 Credit Customization Setting Screen Figure 3-94 Standard Login Page WSG-401 User Manual...
Page 88
Service Selection Page This function allow service provider to customize the additional credit card message for the standard login page. Figure 3-95 Service Selection Page Setting Screen WSG-401 User Manual...
Page 89
Figure 3-96 Example-Service Selection Page WSG-401 User Manual...
Page 91
Figure 3-99 Fail Page Setting Screen Figure 3-100 Example-Fail Page Click Apply button to save the new settings. Click Apply button, the success dialog box appears. Click on Back to return to Credit Card Customization setting screen. Figure 3-101 Success Dialog Box WSG-401 User Manual...
Page 92
This function allow administrator to set some special devices pass through the WSG-401 system. Because some network devices might be constructed under the WSG-401. However these devices needn’t be checked and authorized. The WSG-401 provides a pass through list and the administrator can control which devices can be pass through with authentication.
Page 93
Enter the MAC address of you wants pass through. Mask Empty Enter the subnet mask of you wants pass through. Pass Through List Display the pass through Information of WSG-401. The index number of pass through address. Active Disable Click on check box, active or inactive the pass through address.
Page 94
“http://www.yahoo.com”. The maximum character of the URL Page is 200. Start IP Address Empty Enter the start IP address of you wants to filter. End IP Address Empty Enter the end IP address of you wants to filter. WSG-401 User Manual...
Page 95
Click Add to List button to add a new entry. Click Apply button to save the new settings. Click Delete All & Apply button to delete all entries. Note: The priority of "pass through" is higher than "Filtering". WSG-401 User Manual...
Page 96
Disable Click on check box, active or inactive the share LAN device. Resource Name Display the device name. IP Address Display the IP address of device. MAC Address Display the MAC address of device. Disable Select the check boxes and click ‘Delete’ to delete the share Delete device(s). WSG-401 User Manual...
Page 97
“http://www.yahoo.com”. The maximum character of the URL Link # is 200. Click Apply button to save the new settings. Click Apply button, the success dialog box appears. Click on Back to return to Portal Page setting screen. Figure 3-106 Success Dialog Box WSG-401 User Manual...
Page 98
1~10 the table for advertisement. And these 10 websites will display to the subscribers at random when the subscribers login in the WSG-401 system. The input format can be “http://www.yahoo.com”. The maximum character of the URL Link # is 200.
Page 99
We prepare ten URL links that allows subscriber to access the specific Web pages even they didn’t have a username or password. It’s free trying and can use for advertisement. Yahoo www.yahoo.com www.msn.com Microsoft www.microsoft.com Figure 3-109 Walled Garden WSG-401 User Manual...
Page 100
The input format can be “http://www.yahoo.com”. The maximum character of the URL 1~10 Link# is 200. Click Apply button, the success dialog box appears. Click on Back to return to Walled Garden setting screen. Figure 3-111 Success Dialog Box WSG-401 User Manual...
Page 101
This solves the problems if your DNS server uses an IP associated with dynamic IP addresses. When the ISP assigns the WSG-401 a new IP, the WSG-401 must inform the DDNS server the change of this IP so that the server can update its IP-to-DNS entry. Once the IP-to-DNS table in the DDNS server is updated, the DNS name for your web server (i.e., xyz.dyndns.org) is still usable.
Page 102
Enter your email address. The DDNS Server will e-mail you important information once your Internet Name has been successfully registered. Wildcards (optional) Disable Enable this function able *.mydomain.dyndns.org only mydomain.dyndns.org. Click Apply button to save the new settings. WSG-401 User Manual...
Page 103
Click Apply button, the success dialog box appears. Click on Back to return to DDNS setting screen. Figure 3-113 Success Dialog Box 3-2-17 LAN Devices Administrator can direct remote control to LAN Devices via the WSG-401 implemented the feature. Figure 3-114 LAN Devices Setting Screen Item...
Note: The system does not support FTP. 3-2-18 Syslog The function allows the device to transmit event messages to your syslog server or your email address for monitoring and troubleshooting. l Syslog Setting Figure 3-115 Syslog Setting Screen WSG-401 User Manual...
Page 105
Enables or disables the syslog server function. Syslog on LAN Server IP Address Empty Enter syslog server’s IP address. The WSG-401 will send all of its logs to the specified syslog server. Server MAC Address Empty Enter the syslog server’s MAC address. The WSG-401 will send all of its logs to the specified syslog server.
Page 106
Click Apply button, the success dialog box appears. Click on Back to return to Syslog setting screen. Figure 3-116 Success Dialog Box l Log Categories Figure 3-117 Log Settings Screen WSG-401 User Manual...
Page 107
A log included wireless associated users information would Information be sent according to specified interval time. Format: (Id, Mac Address) (Wireless Association Information, Number of associated users, Start Number, End number) (Signal strength, Signal quality, Connection speed, MAC address)(…)(…)(…) WSG-401 User Manual...
Page 108
Type: TimeToFinish | Accumulation | PostPaid | Super Event: Finished | Replenished | Logout | Idle-Timeout | Account Expired | Deleted If the type of Subscriber Trace is Super, the Username will be “********”, and S/N will be “******”. Usage time: 00:59:59 (example) WSG-401 User Manual...
Page 109
Billing profile name: [Name] Usage time: “00:59:59” (example) Billing profile information: [index, name] Payment: Cash | Credit Card “Credit Card” does not support “PostPaid”. If Type is “PostPaid”, the billing profile information and Units will be “*”. WSG-401 User Manual...
Page 110
(Id, Mac Address) (LAN Device Alarm, Device name, FAIL) Click Apply button to save the new settings. Click Apply button, the success dialog box appears. Click on Back to return to Logs setting screen. Figure 3-118 Success Dialog Box WSG-401 User Manual...
Page 111
Channel Select the channel ID for wireless connection. Disables or enables the use of the WEP algorithm. Enabling the WEP Encryption Disable security can protect your data while it is transferred from one station to another. WSG-401 User Manual...
Page 112
Figure 3-120 WEP Key Setting Item Default Description WEP Encryption 64 bit The WSG-401 supports 64-bit, 128 bit or 256 bit WEP encryption. Mode Options: HEX (Hexadecimal) and ASCII (American Standard Code for Information Interchange). WEP Key This selects which of the Keys the WSG-401 uses when it transmits.
Page 113
This value valid range is 256 - 2342. This setting determines the packet size at which the WSG-401 issues a request to send (RTS) before sending the packet. A low RTS Threshold setting can be RTS Threshold...
Page 114
Diversity Antenna― This default setting tells the device to use the antenna that receives the best signal. If your device has two fixed (non-removable) antennas, you should use this setting for both receive and transmit. WSG-401 User Manual...
Page 115
Both device-requesting authentication encrypts the challenge text and Type sends it back to the WSG-401. If the challenge text is encrypted correctly, the WSG-401 allows the requesting device to authenticate. Both the unencrypted challenge and the encrypted challenge can be monitored, however, which leaves the WSG-401 open to attack from an intruder who calculates the WEP key by comparing the unencrypted and encrypted text strings.
Figure 3-122 Restart Dialog Box This operation will load the default manufacturer configuration to the system. All this page (Wireless) configuration setup will be replaced by default settings. System Status Display WSG-401 system basic status, including, System Account List Account Log...
Page 117
The System Information Menu displays current system basic information including the service connection message, host name, LAN, WAN, DHCP Configuration, DNS, E-mail Redirection, SSL Certificate, network traffic Information and the system firmware version number. Figure 3-124 System Status Screen WSG-401 User Manual...
Page 118
Click the column button to sort the column in ascending/descending order. Select the check boxes and click ‘Delete’ to delete the accounts. Delete all accounts in account list. Note: This page will refresh automatically every 5 minutes. WSG-401 User Manual...
Page 119
This allow you to export the account logs to a text file format. Click on Clear Log to remove all account log entries. Click on refresh button to update the account log page. Click the column button to sort the column in ascending/descending order. WSG-401 User Manual...
Page 120
Click the column button to sort the column in ascending/descending order. Select the check boxes and click ‘Disconnect’ to disconnect accounts. Disconnect all accounts in current user list. 3-3-5 DHCP Clients The DHCP client table shows the current DHCP users on the LAN. WSG-401 User Manual...
Page 121
3-3-6 Session List The remote site administrator could monitor the real time usage status of WSG-401 via this page. Figure 3-128 Session List Screen 3-3-7 LAN Devices You can manage all devices by clicking on device name to access device’s Web-based interface.
SSL Certificate Ping Command Restart Logout Figure 3-131 System Tools Item 3-4-1 Configuration Use the Configuration item to save, restore or reset configuration parameters of the WSG-401. Figure 3-132 Configuration Setting Screen Item Default Description Backup Click it to save the system configuration to your computer.
Page 123
Enter the IP address of TFTP Server. Address File Name Empty Enter the file name in the File Name field. Note: Before downloading the new firmware, users must save the configuration file for restore configuration parameters of the device. WSG-401 User Manual...
Page 124
Enter the IP address of TFTP Server. File Synchronization Empty Enter the file name and location in the File Synchronization field. Click the button to display synchronization file example. Frequency Weekly Set the firmware upgrade time. The default value is “Weekly”. WSG-401 User Manual...
Page 125
Figure 3-135 System Account Setting Screen Item Description Username The username can consist of up to 20 alphanumeric characters and is sensitive. Password The password can consist of up to 20 alphanumeric characters and is sensitive. Confirm The password for confirmation. WSG-401 User Manual...
Press Enter. Figure 3-136 Web Browser Location Field (Factory Default) Step 2: The WSG-401 configuration main menu will appear. Enter “admin” (default) as the Username and “password” (default) as the password and click “Getting Started”. If you are first time setting the system, the wizard setup screen will appear.
Page 127
Step 1: Start your Web browser and enter the factory default IP address 192.168.0.1 in your browser’s location box. Press Enter. Step 2: The WSG-401 configuration main menu will appear. Enter “account” as the Username and “account” as the password and click “Getting Started”...
Page 128
Step 1: Start your Web browser and enter the factory default IP address 192.168.0.1 in your browser’s location box. Press Enter. Step 2: The WSG-401 configuration main menu will appear. Enter “supervisor” as the Username and “supervisor” as the password and click “Getting Started”.
Page 129
Figure 3-142 Subscriber Login Page 3-4-4 SSL Certificate The function allows you to download the registered CA certificate into the WSG-401. Figure 3-143 SSL Certificate Note: The password field must the same as the CA’s registered password. WSG-401 User Manual...
Page 130
Figure 3-144 Ping Command Screen 3-4-6 Restart If your WSG-401 is not operating correctly, you can choose this option to display the restart WSG-401 screen. Clicking the apply button restart the WSG-401, with all of your settings remaining intact. Figure 3-145 Restart Screen 3-4-7 Logout If you would like to leave the configuration page, please click apply to exit.
Appendix A RJ-45 Connector Description RJ-45 Ethernet Port The WSG-401 RJ-45 Ethernet port can connect to any networking devices that use a standard LAN interface, such as a Hub/Switch Hub or Router. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable to connect the networking device to the RJ-45 Ethernet port.