Technical Information
Master Model Code
Series 90 Master Model Code
Series 90 Master Model
Code
R
Type and Rotation
R
Right Hand [CW]
L
Left Hand [CCW]
Size
042
42 cc [2.56 in
3
] max. displacement per revolution
055
55 cc [3.36 in
3
] max. displacement per revolution
075
75 cc [4.58 in
3
] max. displacement per revolution
100
100 cc [6.10 in
3
] max. displacement per revolution
130
130 cc [7.93 in
3
] max. displacement per revolution
180
180 cc [10.98 in
3
] max. displacement per revolution
250
250 cc [15.26 in
3
] max. displacement per revolution
M
Controls
CA
cover plate without feedback link, no control
DC
3 positon F-N-R solenoid control (12 V , DC) DIN- connector
DD
3 positon F-N-R solenoid control (24 V , DC) DIN- connector
HF
HDC 2, std. porting, 3,0 - 11 BAR (44 - 160 PSI)
KA
EDC, MS connector, std. porting, dual coil (14 - 85 mA)
KN
EDC, MS connector, std. porting, 643 Ohm single coil (4 - 20 mA)
KT
EDC, Deutsch connector, std porting, dual coil ( 14 - 85 mA)
KP
EDC, Weatherpack connector, std. porting, dual coil (14 - 85mA)
MA
MDC
MB
MDC with neutral start switch
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
FA
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
FB
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
FC
connector, proportional solenoid with pressure reducing valve ( 32 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
FD
connector, proportional solenoid with pressure reducing valve ( 32 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
FG
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
FH
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
FK
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
FL
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
FM
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
FN
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
Series 90 Axial Piston Pumps
R
Size
M
P
J
S90
520L0603 • Rev 0804 • March 2016
G
N F
L
H
T
W
042
O
O
042
O
042
O
O
O
O
O
O
O
O
O
O
O
O
O
Y
Z
K
055
075
100
130
180
O
O
O
O
O
O
O
O
O
O
055
075
100
130
180
O
O
O
O
O
055
075
100
130
180
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
250
O
O
250
O
250
O
O
O
O
O
O
O
O
O
21
Need help?
Do you have a question about the Series 90 and is the answer not in the manual?