Programming
P P ar.
Parameter description
No. #
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
5
5
1-67
Load Type
1-68
Minimum Inertia
1-69
Maximum Inertia
1-7* Start Adjustments
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-74
Start Speed [RPM]
1-75
Start Speed [Hz]
1-76
Start Current
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-83
Precise Stop Function
1-84
Precise Stop Counter Value
1-85
Precise Stop Speed Compensation Delay
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Resource
1-94
ATEX ETR cur.lim. speed reduction
1-95
KTY Sensor Type
1-96
KTY Thermistor Resource
1-97
KTY Threshold level
1-98
ATEX ETR interpol. points freq.
1-99
ATEX ETR interpol points current
38
inverter.ru
(812) 702-47-50
VLT Decentral Drive FCD 302 Operating Instructions
Default value
100 %
100 %
App.Dependent
App.Dependent
100 %
5 ms
100 %
[0] Passive load
App.Dependent
App.Dependent
0.0 s
[2] Coast/delay time
null
App.Dependent
App.Dependent
0.00 A
[0] Coast
App.Dependent
App.Dependent
[0] Precise ramp stop
100000 N/A
10 ms
[0] No protection
[0] No
[0] None
0.0%
[0] KTY Sensor 1
[0] None
80 °C
App.Dependent
App.Dependent
MG.04.F2.02 - VLT is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
FALSE
All set-ups
x
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
1 set-up
x
TRUE
1 set-up
x
TRUE
2 set-ups
x
TRUE
Conver-
Type
sion index
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
0
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-1
Uint8
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
-2
Uint32
-
Uint8
67
Uint16
-1
Uint16
-
Uint8
0
Uint32
-3
Uint8
-
Uint8
-
Uint16
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
100
Int16
-1
Int16
0
Int16