REMOVING / REPLACING THE MICROPHONE
Proc Sheet 1 08
myX-3 & myX-5
1/2
4.61 Tools :
- A 0.6mm torx screwdriver
- Tweezers
4.62 Preliminary operation
1. Remove the back cover (
Proc sheet 0
01).
2. Remove the battery (
Proc sheet 0
02).
3. Remove the front cover (
Proc sheet 0
03).
4. Unscrew the six attachment screws on the electronic board.
5. Remove the assembly display , then the light guide keypad
(Proc sheet 1 02 / 1 03)
6. Remove the electronic
board.(Proc sheet 1
04)
4.63 Removal procedure:
1. Remove the microphone (1) , using tweezers.
4.64 Placement procedure :
1. Put the microphone (1) in position in its housing (2).
4.65 Further operations :
1. Remove the electronic board on the assembly plate.
.(Proc sheet 1
04)
2. Replace the light guide keypad
(Proc sheet
1.03)
3. Replace the assembly display
(Proc sheet 1 02)
4. Position and tighten the six attachments screws with torx settings of 0,25 N.m.
5. Replace the front cover /battery / back cover
(Proc sheet 0 01 / 0 02 / 0
03).
6. Carry out the radio test
(Test Sheet
06).
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002