Sagem myX-5 Technical Documentation Manual page 78

Gsm 900/1800
Hide thumbs Also See for myX-5:
Table of Contents

Advertisement

REMOVING / REPLACING THE ELECTRONIC
Proc Sheet 1 04
BOARD
myX-3 & myX-5
1/2
4.41 Tools :
- A 0.6mm torx screwdriver
4.42 Preliminary operation
1. Remove the back cover (
Proc sheet 0
01).
2. Remove the battery (
Proc sheet 0
02).
3. Remove the front cover (
Proc sheet 0
03).
4.43 Removal procedure :
1. Unscrew the six attachment screws on the assembly plate (2)
2. Remove the assembly display
(Proc sheet 1 02)
3. Remove the light guide keypad
(Proc sheet 1 03)
4. Remove the electronic board (1) on the assembly plate
(2).(Proc sheet 1
10)
4.44 Placement procedure :
1. Replace the new electronic board on the assembly plate
(2).(Proc sheet 1
10)
2. Replace the light guide keypad on its housing.
3. Replace the assembly display
(Proc sheet
1.02)
4. Position and tighten the six attachments screws with torx couple of 0,25 N.m.
4.45 Further operations :
1. Replace the front cover
(Proc sheet 0
03).
2. Replace the battery
(Proc sheet 0
02).
3. Replace the back cover
(Proc sheet 0
01).
4. Carry out the radio test
(Test Sheet
06).
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002