Sagem myX-5 Technical Documentation Manual page 54

Gsm 900/1800
Hide thumbs Also See for myX-5:
Table of Contents

Advertisement

myX-3 & myX-5
This test checks the various battery chargers.
Required tools
a voltmeter (minimum impedance 20 kΩ per Volt in DC),
two sockets for banana connectors for connection to the voltmeter,
a charger test kit.
Test procedure
Two terminals are used for measurements on the charger test kit
red (+),
black (-).
A pushbutton selects the measurement :
at no load (released position),
under load (pushed in position).
7.
Check visually the charger connector.
8.
Connect the charger to be tested to the back of the tester.
9.
Connect the voltmeter using the two banana connectors.
10. Before starting any other measurement, check that the charger is correctly powered (mains voltage conform with
the charger specifications).
11. Make the two measurements.
12. Check the recorded values using the following table.
Charger
Travel 500 mA
Simple 300 mA
cigar lighter
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002
CHARGER TEST
Test description
At no load
Min.
Max.
5,5 V
7,5 V
9 V
15 V
5,5 V
7,5 V
Test Sheet 02
Under load
Min.
Max.
2 V
4 V
1,5 V
4 V
2 V
4 V
1/1
Page 4-48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Myx-3