myX-3 & myX-5
Test description
This test tests the battery consumption.
Required tools
myX-3 Ammeter interface
myX-5 Ammeter interface
An Ammeter.
Test procedure
Measurement when switched off
17. Insert the mobile (switched off) onto the tool (customer phone and battery).
18. Connect the ammeter to the tool between A poles:
Red tool terminal on the ammeter "COM" or "GND" terminal.
Black tool terminal on the ammeter "+" terminal.
NOTE: The ammeter rating must be set to DC (DC or =), range 100 mA.
19. The value shown must be less than 1 mA.
20. Disconnect the ammeter from the tool and remove the mobile from the tool, with the battery.
Measuring the charge
21. Insert the mobile (switched off) onto the tool (customer phone and battery).
22. Connect the ammeter to the tool between A poles:
Black tool terminal on the ammeter "COM" or "GND" terminal.
Red tool terminal on the ammeter "+" terminal.
NOTE: The ammeter rating must be set to DC (DC or =), range 1 A.
23. Connect the customer's charger when energised (after connecting the charger to the mains power supply).
24. The recorded value must be greater than 150 mA.
NOTE:
When changing the ammeter rating (manual or automatic), the mobile can be disconnected.
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002
CONSUMPTION TEST
Test Sheet 04
1/1
Page 4-50