Fig. 3-73
There are several versions of the V/f characteristic as shown in Table 3-23.
Table 3-23
Parameter
value
0
1
2
3
166
U, M, P, Φ
, Φ
M
n
n
U, P
Voltage control range
Operating ranges and characteristics of an induction motor when fed from a
drive inverter
V/f characteristic (parameter P1300)
Use / property
Significance
Linear
Standard case
character-
istic
FCC
Characteristic which compensates the voltage losses of the stator
resistance for static (steady-state) or dynamic loads (flux current control
FCC). This is especially used for small motors which have a relatively high
stator resistance.
Square-law
This is a characteristic which
character-
takes into consideration the
istic
torque characteristic of the driven
load (e.g. fan / pump)
a) Square-law characteristic
2
(f
characteristic)
b) Energy saving as the lower
voltage also results in lower
currents and losses.
Programm-
Characteristic which takes into
able
consideration the torque
character-
characteristic of the motor /
istic
driven load (e.g. synchronous
motor).
U, P
Rated motor
operating point
M, Φ
Field control range
f
f
n
max
V
V
n
P1300 = 0
0
V
V
n
P1300 = 2
0
V
V
max
r0071
V
n
P0304
P1300 = 3
P1325
P1323
P1321
P1310
f0
f1
f2
0 Hz
P1320
P1322
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
Issue 10/03
f
f
f
n
f
f
n
f
f3
f
f
n
max
P1324
P0310
P1082