Table 7-5 Compliance Table - Siemens MICROMASTER 440 Operating Instructions Manual

Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

7 Electro-magnetic compatibility
Table 7-5
Compliance Table
Frame Sizes A to F
Model
Class 1 – General Industrial
6SE6440-2U***-**A1
Class 2 – Filtered Industrial
6SE6440-2A***-**A1
6SE6440-2A***-**A1 with
6SE6440-2FA00-6AD1
Class 3 – Filtered for residential, commercial and light industry
6SE6440-2U***-**A1 with
6SE6400-2FB0*-***1
* denotes any value is allowed.
Frame Sizes FX to GX
Model
Class 1 – General Industrial
6SE6440-2U***-**A1
Class 2 – Filtered Industrial
6SE6440-2U***-**A1
208
Remarks
Unfiltered units, all voltages and powers.
All units with integral Class A filters
Frame size A units 400-480 V with external Class A footprint filters
Unfiltered units fitted with external Class B footprint filters.
Remarks
Unfiltered units, all voltages and powers.
With EMI filter (available as an option) the limiting values of the
EN 55011, Class A are fulfilled for conducted emission.
(line commutating choke required)
MICROMASTER 440
Issue 10/03
Operating Instructions
6SE6400-5AW00-0BP0