3 Functions
With JOG ?
no
yes
JOG frequency right
P1058 = 5
Frequency in Hz when the motor is being jogged in the clockwise
direction of rotation.
JOG frequency left
P1059 = 5
Frequency in Hz when the motor is being jogged in the counter-
clockwise direction of rotation.
JOG ramp-up time
P1060 = 45
Ramp-up time in s from 0 to
the maximum frequency
(P1082). The JOG ramp-up is
limited by P1058 or P1059.
JOG ramp-down time
P1061 = 50
Ramp-down time in s from the
maximum frequency (P1082)
to 0.
With
suppl. setpoint ?
no
yes
BI: Disable additional setpoint
P1074 = 1.0
Disables the additional setpoint.
CI: Additional setpoint
P1075 = 755
Defines the source of the additional setpoint which is added to the main
setpoint.
Common settings:
CI: Additional setpoint scaling
P1076 = 1.0
Defines the source to scale the additional setpoint.
Common settings:
With skip
frequency ?
no
yes
Skip frequency 1
P1091 = 7.5
(entered in Hz)
Avoids mechanical resonance effects
and suppresses (skips) frequencies in
the range around the skip frequency
± P1101 (skip frequency bandwidth).
Skip frequency 2
P1092 = 0.0
Skip frequency 3
P1093 = 0.0
Skip frequency 4
P1094 = 0.0
92
755 Analog input setpoint
1024 Fixed frequency setpoint
1050 MOP setpoint
1 Scaling of 1.0 (100 %)
755 Analog input setpoint
1024 Fixed frequency setpoint
1050 MOP setpoint
f
P1082
(f
)
max
P1058
P1060
f
out
P1091
Skip frequency
MICROMASTER 440
Issue 10/03
t
P1061
P1101
Skip frequency
bandwidth
f
in
Operating Instructions