Rx Servotest - GRAUPNER MX-10 HOTT Programming Manual

Table of Contents

Advertisement

Available languages

Available languages

wish to use the RX CURVE option - then two curves
must be set:
RX CURVE
CURVE1 CH
:
02
TYPE :
CURVE2 CH
:
05
TYPE :
CURVE3 CH
:
04
TYPE :
5CH FUNCTION:SERVO
If you ignored this, the left and right ailerons would
exhibit different control characteristics.
The RX CURVE function can be used to manage the
control characteristics for up to three servos:
CURVE 1, 2 or 3 CH
Select the desired control channel (INPUT CH) for
the fi rst servo.
The following setting in TYPE only affects the chan-
nel you select at this point.
TYPE
Select the servo curve:
A: EXPO = -100% and DUAL RATE = 125%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
B: Linear setting
The servo follows the stick movement with a linear
response.
C: EXPO = +100% and DUAL RATE = 70%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
Note:
The control characteristics programmed at this point
also affect mapped receiver outputs.
RX SERVO TEST
RX SERVO TEST
A
ALL–MAX
ALL–MIN
A
TEST
ALARM VOLT : 3.8V
B
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUTPUT TYPE:ONCE
Value
Explanation
ALL-MAX
Servo travel on
the "+" side for all
servo outputs in
the servo test
ALL-MIN
Servo travel on
the "-" side for all
servo outputs in
the servo test
TEST
Test procedure
ALARM
Alarm limit for the
VOLT
receiver low-
voltage warning
ALARM
Alarm limit for
TEMP+
excessive receiver
temperature
ALARM
Alarm limit for
TEMP–
excessively
low receiver
temperature
CH OUTPUT
Channel sequence ONCE, SAME,
TYPE
ALL MAX (maximum servo travel)
In this line you can set the maximum servo travel for the
servo test on the plus side of control travel.
2000 μs corresponds to full travel, 1500 μs corresponds
: 2000—sec
to the neutral position.
: 1000—sec
: STOP
ALL MIN (minimum servo travel)
In this line you can set the maximum servo travel for the
servo test on the minus side of control travel.
1000 μs corresponds to full travel, 1500 μs corresponds
to the neutral position.
Possible settings
TEST
1500 ... 2000 μs
In this line you can start and stop the receiver's integral
servo test.
Press the
1500 ... 1000 μs
START / STOP
3,0 ... 6,0 V
Default setting:
Now select
3,8 V
right-hand four-way button:
50 ... 80 °C
Default setting:
70 °C
-20 ... +10 °C
Default setting:
-10 °C
Press the
input fi eld now reverts from highlighted to "normal":
SUMI, SUMO
INC+DEC
button to activate the input fi eld:
RX SERVO TEST
ALL–MAX
: 2000—sec
ALL–MIN
: 1000—sec
TEST
:
STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUTPUT TYPE:ONCE
START
with one of the arrow buttons of the
RX SERVO TEST
ALL–MAX
: 2000—sec
ALL–MIN
: 1000—sec
TEST
:
START
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUTPUT TYPE:ONCE
INC+DEC
button to start the test-run. The
Program description: Telemetry menu
121

Advertisement

Table of Contents
loading

Table of Contents