ceiving stations. This last option instructs the receivers to reboot to a specific firmware revision
if available, and not already running at that revision.

Cancelling OTA Reprogramming

During the reprogramming operation the user has the ability to cancel reprogramming at any
time either on the initiator, which will affect all radios, or on individual receiving stations. Note
that cancelling reprogramming at the initiator results in all radios in the network having only one
(instead of two) applications programmed in their image banks. That is, the "inactive" image
(which was only partially upgraded) and will be corrupt and unusable until reprogrammed at a
later time.

Error Conditions/Recovery

Other than cancelling the reprogramming process, there are few error conditions that the initiator
knows or can do anything about. Receiving radios perform checks and verification on the incom-
ing data. If after the end of the reprogramming sequence a radio still has an invalid image (for
whatever reason) the radio will not reboot but continue running with its active, and valid image.

Execution and Screen Examples

User Data Explanations
Displayed information during reprogramming (at Root radios):
(Percent Complete — Read-only): This parameter indicates percent complete of
Progress
a firmware upgrade. The calculation is done each time a block of data is successfully
transmitted or received. Must be viewed on the
User Command explanations
Command options available during reprogramming (at Root radios):
Stop Remote Reprogramming
in the network. Inactive images on non-root radios will be invalid. (No change to status
of root radio images)
Reboot Remote to
mote nodes will reboot to their image selected.
Command options available during reprogramming (at "Non-Root" radios):
Stop Remote Reprogramming
tive image will be invalid.
Screen Example
Figure 44 shows the radio's
MDS 05-4864A01, Rev. I
— Terminate remote firmware upgrade for all remote nodes
— Manually send a reboot to all remote nodes in the network. All re-
— Terminate Remote Reprogramming for local radio. Inac-
Remote Reprogramming
SD Series Technical Manual
screen.
Reprogramming
Screen.
93