3M™ Multi-Touch Chassis Display User Guide

Intended Use

The 3M™ Touch Displays are designed for touch input and tested to replace an existing
display. These displays are intended for professional installation and use in an indoor,
business environment. They are not designed or tested for use in hazardous locations.
Use in any other application has not been evaluated by 3M and may lead to an unsafe
condition. Not intended for household or personal use.

Important Notes

In extreme temperature and humidity situations, you may observe condensation between the sensor and
the display. To minimize this condition, place the unit where it will be used and allow a 24-hour
environmental stabilization period prior to powering on the display. Any noticeable condensation is
temporary and will have no long term effect on the operation of the display.
You are cautioned that any change or modification to the equipment not expressly approved by the party
responsible for compliance could void your warranty.
When unplugging the power supply cord, hold the plug, do not pull by the cord.
Do not connect or disconnect this product during a thunder storm or lightning.
Remember to take into account that the operating temperature of the installation may be greater than the
room ambient, and consideration should be given to installing the unit in an environment compatible with
the maximum rated operating temperature. Specifications can be found in the product data sheet on the
3M Touch Systems website at http://www.3m.com/touch/.
The 3M Multi-Touch Chassis Display may not function as expected at altitudes higher than 2000 meters.
3M Touch Systems recommends to vacuum or replace the fan filter at least every six months or if a
noticeable rise in surface temperature occurs.
When installing the unit, ensure that it does not restrict the flow of air to any other equipment within the
installation required for safe operation.
An inherent characteristic of the 3M Projected Capacitive Touch (PCT) sensor is a fine grid pattern that
may be visible under certain lighting conditions.
Install the display in a well-ventilated area. Always maintain adequate ventilation to protect the display
from overheating and to ensure reliable and continued operation.
Do not expose this display to direct sunlight or heat. Passive heat may cause damage to the housing and
other parts.
Do not install this display in areas where extreme vibrations may be generated. For example, nearby
manufacturing equipment may produce strong vibrations. The vibrations may cause the display to exhibit
picture discoloration or poor video quality.
The 3M touch controllers mentioned in this document are USB compatible full speed devices.
3M does not warrant that we are USB compliant pursuant to USB specifications.
Cooling fan will cycle based on internal temperature. When the internal temperature grows higher than
ambient, the fan will turn on.
System will shut down when internal temperature reached a critical level