Installing the Rack Mount
ET 350 Monitor (Model 350R), ET 3170 Terminal, and ET 3200 Series Computers

Intended Use

When properly installed using the materials provided, and
according to these instructions, the rack mount is intended
to mount the 3M Dynapro
terminal, and ET 3200 series computers for use in a
standard 19-inch EIA rack.
Product safety information
Read and understand all safety information in this
document before installing and using the rack mount.
WARNING
To reduce the risks associated with fire and explosion
which, if not avoided, could result in death or serious injury
and/or property damage.
Use the materials provided so that installation of the ET unit will
!
not result in a hazardous condition due to uneven mechanical
loading.
WARNING
To reduce the risks associated with electrical shock or fire
which, if not avoided, may result in death or serious injury
and/or property damage:
Follow all product and accessory installation instructions.
!
WARNING
To reduce the risks associated with electrical shock or fire
which, if not avoided, could result in death or serious injury
and/or property damage:
Reliable earthing of rack-mounted equipment should be
!
maintained. Particular attention should be given to supply
connections other than direct connections to the branch circuit
(e.g., use of power strips).
Consideration should be given to the connection of the ET unit to
!
the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
TM
ET 350 monitor, the ET 3170
3M Touch Systems Proprietary Information
CAUTION
To reduce the risks associated with fire which, if not
avoided, may result in minor or moderate injury or cause
property damage.
Installation of the ET unit in a rack should be such that the
!
amount of air flow required for safe operation of the unit is not
compromised.
Equipment
Materials supplied
The Rack Mount Kit comes with the following items:
1 rack adapter (the example illustrated below is the
!
adapter for the ET 3170 terminal or ET 3210
computer)
8 clip nuts
!
12 Phillips #10-32 x ½ inch panhead machine screws
!
12 flat washers
!
12 lock washers
!
8 slotted #10-32 x 5/8 inch countersunk machine
!
screws
8 cup washers
!

Tools Required

No. 2 Phillips screwdriver
!
Large flat-blade screwdriver
!
1
73145_a

Advertisement

loading

Summary of Contents for 3M Dynapro ET 350 R

  • Page 1: Intended Use

    3M Dynapro ET 350 monitor, the ET 3170 Installation of the ET unit in a rack should be such that the...
  • Page 2 Tighten each screw to a torque of 12 inch-pounds. If your unit requires security screws (available as an option from 3M Touch Systems), insert them. Pick up the rack adapter with the ET unit attached and fit it to the rack. Position it to match the locations of the clips installed earlier.
  • Page 3 If the Product, software or software media is performance of a 3M Touch Systems Product (the proven not to have met 3M Touch Systems’ warranty, then “Product”), including that solid state equipment has 3M Touch Systems’ sole obligation and User’s and operation characteristics different from electromechanical Purchaser’s exclusive remedy, will be, at 3M Touch...