Figure 4-1. Software Displays Relative To System Auto Calibration I/O Module - Emerson NGA2000 Instruction Manual

Hide thumbs Also See for NGA2000:
Table of Contents

Advertisement

Model NGA2000 I/O Modules
Expert controls and setup
Expert analyzer controls...
Auxiliary module controls...
System set up...
Analyzer Module set up...
Auxiliary Module set up...
Auxiliary module controls
This screen selects any module with a control
screen. This includes any auto calibration or
sample module bound to the analyzer.
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Auxiliary module set up
Select an auxiliary module for set up
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
System Auto Cal Module
Automatic calibration initiation...
Manual calibration initiation...
Timing parameters...
Valve control parameters...
General parameters...
Number of zeros before the next span:
Analyzer identification...
Slot position
Automatic Calibration Initiation
See #1 above.
Manual Calibration Initiation
See #2above.
Timing parameters
Start sequence at this time-Day of month: 4
Start sequence at this time - Hrs:
Start sequence time - mins:
Calibration cycle period:
Local zero gas dwell time:
Local span gas dwell time:
Local sample dwell time:
Remote zero gas dwell time:
Remote span gas dwell time:
Remote sample dwell time:
Valve control parameters
Zero gas valve...
Span valve 1...
Span valve 2...
Span valve 3...
Span valve 4...
General parameters
Timed function:
Zero checks per span checks:
Input line control:
This modules control status:
Analyzer identification
Analyzer 1 tag:
Analyzer 2 tag:
Analyzer 3 tag:
Analyzer 4 tag:
Analyzer 1 range:
Analyzer 2 range:
Analyzer 3 range:
Analyzer 4 range:
(Set up ranges in the analyzer menus)

Figure 4-1. Software Displays Relative to System Auto Calibration I/O Module

Rosemount Analytical Inc.
A Division of Emerson Process Management
Main Menu
Basic Controls...
Expert controls and setup...
(Operational Configuration)
Technical level configuration...
(Diagnostic and manufacturing/service)
#1
Automatic calibration initiation
Gas selected:
Calibration mode:
Analyzer status:
Calibration cycle status:
Analyzer 1 output:
Analyzer 2 output:
Analyzer 3 output:
Analyzer 4 output:
Manual calibration function...
#2
Manual calibration initiation
Gas selected:
Calibration mode:
Span gas valve selected:
Analyzers affected:
Analyzer status:
Calibration cycle status:
Select appropriate gas, press START
0
1
4
0
12 hrs
2 min
2 min
1 min
2 min
3 min
Zero gas valve
1 min
Analyzers affected:
Operation performed:
Current status:
Operates on ranges as selected in the
analyzer.
Span gas valve 1 (2,3,4)
Analyzers affected:
Operation performed:
Current status:
Analyzer 1 range:
Cal
Analyzer 2 range:
4
Analyzer 3 range:
Enabled
Analyzer 4 range:
Master
Range List
CO
Range 1 lower limit:
CO
Range 1 upper limit:
CO
Range 2 lower limit:
CO
Range 2 upper limit:
2
Range 3 lower limit:
1
Range 3 upper limit:
3
Range 4 lower limit:
3
Range 4 upper limit:
Technical configuration menu
System set up...
Service menus...
Diagnostic menus...
Other module diagnostic menus...
Listing of all modules...
System Set Up
Sample
Main display configuration...
Local
Front panel control...
Ready
Date and time...
Sample
Miscellaneous control set up...
110 ppm
Module binding...
90 ppm
Interference binding...
100 ppm
System reset...
100 ppm
Record security codes...
System tag:
Service Menus
Manufacturing data...
Sample
Service history...
Local
Review stored data...
1
In maintenance since:
1&2
Maintenance alert messages...
Ready
Record security codes...
Sample
Manufacturing data
Control module data...
Analyzer module data...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
System Auto Cal Module
Issue 1, 7-31-94
Software version:
Subnode base name:
Subnode 1 identification:
Subnode 2 identification:
Subnode 3 identification:
Subnode 4 identification:
System auto cal module ID: Auto 1043
Diagnostic menus
Control module diagnostics...
Analyzer module diagnostics...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
All
Module Tag
Zero
Module Tag
Ready
System Auto Cal Module
Power supplies...
1&2
Relay status...
Zero
Digital input lines...
Ready
Slot position:
1
IO module ID
1
1
1
Other module diagnostics
This screen reserved for other modules if
present:
0 ppm
Module Tag
10 ppm
Module Tag
0 ppm
Module Tag
100 ppm
Module Tag
0 ppm
Module Tag
250 ppm
Module Tag
0 ppm
Module Tag
1000 ppm
Instruction Manual
Module Binding
Analyzer module selected: CLA 1023
Select modules...
Proposed bind:
View bindings...
Bind selections!
Unbind everything!
Select IO modules
Select the modules you wish to bind to the
current analyzer.
Module Tag
Module Tag
Module Tag
Modules Bound
Analyzer module selected:
Auxiliary module:
Auxiliary module:
Rosemount
Auxiliary module:
Auxiliary module:
Auxiliary module
Auxiliary module:
Proposed new bind:
N/A
2.1
For:
For: 1
For: 2
For: 3
For: 4
Analog module power supplies
+15V analog is:
+15V analog was:
-15V analog is:
-15V analog was:
+5V digital is:
+5V digital was:
Relay status
Relay function:
(Set this to TEST to set relays below)
1
Relay 1 status:
Auto 1043
Relay 1 measures:
Relay 2 status:
Relay 2 measures:
Relay 3 status:
Relay 3 measures:
Input line status
Line 1 status:
Line 2 status:
Line 3 status:
Line 4 status:
Line 5 status:
Line 6 status:
System Auto Calibration I/O Module
748275-F
September 2003
CLA 1023
Auto 1023
Acal 2322
HART 1092
None
None
None
14.98 V
14.87 V
-14.92 V
-14.98 V
4.98 V
5.02 V
Auto
On
On
On
On
On
On
OFF
OFF
OFF
OFF
OFF
OFF
4-3