Figure 3-1. Software Displays Relative To Auto Calibration I/O Module - Emerson NGA2000 Instruction Manual

Hide thumbs Also See for NGA2000:
Table of Contents

Advertisement

Instruction Manual
748275-F
September 2003
Expert controls and setup
Expert analyzer controls...
Auxiliary module controls...
System set up...
Analyzer Module set up...
Auxiliary Module set up...
Auxiliary module controls
This screen selects any module with a control
screen. This includes any auto calibration or
sample module bound to the analyzer.
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Auxiliary module set up
Select an auxiliary module for set up
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Auto Cal Module
Automatic calibration initiation...
Manual calibration initiation...
Timing parameters...
Valve control parameters...
General parameters...
Number of zeros before the next span:
0
Analog output parameters...
Slot position
1
Automatic Calibration Initiation
See #1 above.
Manual Calibration Initiation
See #2above.
Timing parameters
Start sequence at this time-Day of month: 4
Start sequence at this time - Hrs:
4
Start sequence time - mins:
0
Calibration cycle period:
12 hrs
Zero gas dwell time:
2 min
Span gas dwell time:
2 min
Sample dwell time:
1 min
This modules control status:
Master
Valve control parameters
Zero gas valve...
Span valve 1...
Span valve 2...
Span valve 3...
Span valve 4...
General parameters
Timed function:
Cal
Zero checks per span checks:
4
Input line control:
Enabled
Analog output parameters
Parameter reported:
CO
Voltage or current:
0-5V
Output value on analyzer failure:
0
Output hold on validity:
Yes
Output hold on maintenance:
Yes
Output hold on calibration:
Yes
List range limits...
Figure 3-1. Software Displays Relative to
Auto Calibration I/O Module
3-2
Auto Calibration
Main Menu
Basic Controls...
Expert controls and setup...
(Operational Configuration)
Technical level configuration...
(Diagnostic and manufacturing/service)
#1
Automatic calibration initiation
Gas selected:
Sample
Measurement range number:
1
Analyzer status:
Ready
Calibration cycle status:
Sample
Time remaining on this step:
10 Sec
Press START to initiate a zero and span.
Manual calibration function...
#2
Manual calibration initiation
Gas selected:
Sample
Measurement range number:
1
Analyzer status:
Ready
Calibration cycle status:
Sample
Time remaining on this step:
10 Sec
Zero gas valve
Operates on ranges as selected in the
analyzer.
Operation performed:
Zero
Current status:
Ready
Span gas valve
Analyzer range used:
1
Operation performed:
Zero
Current status:
Ready
Range List
Range 1 lower limit:
0 ppm
Range 1 upper limit:
10 ppm
Range 2 lower limit:
0 ppm
Range 2 upper limit:
100 ppm
Range 3 lower limit:
0 ppm
Range 3 upper limit:
250 ppm
Range 4 lower limit:
0 ppm
Range 4 upper limit:
1000 ppm
Model NGA2000 I/O Modules
Technical configuration menu
System set up...
Service menus...
Diagnostic menus...
Other module diagnostic menus...
Listing of all modules...
System Set Up
Main display configuration...
Front panel control...
Date and time...
Miscellaneous control set up...
Module binding...
Interference binding...
System reset...
Record security codes...
System tag:
Rosemount
Service Menus
Manufacturing data...
Service history...
Review stored data...
In maintenance since:
N/A
Maintenance alert messages...
Manufacturing data
Control module data...
Analyzer module data...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
IO Unit manufacturing data
Issue 2, 4-4-94.
Software version:
2.0
IO module ID:
Auto 1043
Diagnostic menus
Control module diagnostics...
Analyzer module diagnostics...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Automatic calibration module
Power supplies...
Analog output...
Relay status...
Digital input lines...
Slot position:
1
IO module ID
Auto 1043
Other module diagnostics
This screen reserved for other modules if
present:
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Rosemount Analytical Inc.
Module Binding
Analyzer module selected: CLA 1023
Select modules...
Proposed bind:
View bindings...
Bind selections!
Unbind everything!
Select IO modules
Select the modules you wish to bind to the
current analyzer.
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Modules Bound
Analyzer module selected:
CLA 1023
Auxiliary module:
Auto 1023
Auxiliary module:
Acal 2322
Auxiliary module:
HART 1092
Auxiliary module:
Auxiliary module
Auxiliary module:
Proposed new bind:
Analog module power supplies
+15V analog is:
14.98 V
+15V analog was:
14.87 V
-15V analog is:
-14.92 V
-15V analog was:
-14.98 V
+5V digital is:
4.98 V
+5V digital was:
5.02 V
IO Module Analog Output Diagnostics
Theoretical output voltage -V:
0.784 V
Theoretical output current-mA:
1.567mA
Measured output voltage -V:
0.762 V
Voltage on current terminals -V:
0.162 V
Output load -ohms:
200 ohms
Calculated output current -mA:
12.1mA
Diagnostics limits...
Voltage output calibration...
Current output calibration...
Analog Output Diagnostic Limits
Voltage output error:
Maximum current load:
Minimum current load:
0 mA under-current limit -mA:
4 mA under-current limit -mA:
20 mA over-current limit -mA:
0V under-voltage limit -V:
5V under-voltage limit -V:
Voltage output calibration
Voltage/current mode:
Desired output voltage:
Measured output voltage:
Zero offset:
Gain factor:
Set to test for calibration:
Set desired output voltage: Adjust the measured voltage
with the zero and gain factors. Then set to auto.
Current output calibration
Voltage/current mode:
Desired output current:
Measured output current:
Zero offset:
Gain factor:
Set to test for calibration:
Set desired output current: Adjust the measured voltage
with the zero and gain factors. Then set to auto.
Relay status
Relay function:
(Set this to TEST to set relays below)
Relay 1 status:
Relay 1 measures:
Relay 2 status:
Relay 2 measures:
Relay 3 status:
Relay 3 measures:
Input line status
Line 1 status:
OFF
Line 2 status:
OFF
Line 3 status:
OFF
Line 4 status:
OFF
Line 5 status:
OFF
Line 6 status:
OFF
A Division of Emerson Process Management
None
None
None
1%
600 ohms
10 ohms
-1 mA
3.9 mA
20.8 mA
-0.5 V
5.5 V
0-5 V
0 V
0.762 V
0 V
0
Auto
0-5 V
0 V
12.1mA
0 V
0
Auto
Auto
On
On
On
On
On
On

Advertisement

Table of Contents
loading

Table of Contents