Page 1
Instruction Manual 748275-F September 2003 Model NGA2000 I/O Modules http://www.processanalytic.com...
Page 2
• Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being performed by qualified persons, to prevent electrical shock and personal injury. The information contained in this document is subject to change without notice. Emerson Process Management Rosemount Analytical Inc. Process Analytic Division 1201 N. Main St.
Connections...........................1-3 Specifications.........................1-5 ANALOG OUTPUT/3 ALARMS....................2-1 Overview..........................2-1 Installation..........................2-3 AUTO CALIBRATION......................3-1 Overview..........................3-1 Installation..........................3-3 SYSTEM AUTO CALIBRATION...................4-1 Overview..........................4-1 Installation..........................4-2 RETURN OF MATERIAL ......................5-1 Return Of Material .........................5-1 Customer Service ........................5-1 Training..........................5-1 748336 ADDENDUM Rosemount Analytical Inc. A Division of Emerson Process Management Contents...
Page 4
Available Functions – Analog Output with 3 Alarms I/O Module ......2-4 Table 3-1. Available Functions – Auto Calibration I/O Module ..........3-4 Table 4-1. Available Functions – System Auto Calibration I/O Module ........4-4 Contents Rosemount Analytical Inc. A Division of Emerson Process Management...
The purpose of this manual is to provide information concerning the components, functions, installation and maintenance of the Model NGA2000 I/O Modules and the System Accessories of the NGA2000 System. Some sections may describe equipment not used in your configuration. The user should become thor- oughly familiar with the operation of this module before operating it.
NOTICE Software compatibility is necessary for all NGA2000 components in your system to work together. The version of your Platform's software must be equal to or greater that the version of any other module(s) for successful compatibility. If it is not, contact Rosemount Analytical at 800-441-7245 to order software upgrade kit PN 657150 for the Platform.
8. Do not place cylinders where they may become part of an electric circuit. When electric arc welding, precautions must be taken to prevent striking an arc against the cylinder. Rosemount Analytical Inc. A Division of Emerson Process Management Preface...
Instruction Manual 748275-F Model NGA2000 I/O Modules September 2003 DOCUMENTATION The following NGA2000 I/O Modules instruction materials are available. Contact Customer Service Cen- ter or the local representative to order. 748275 Instruction Manual (this document) Preface Rosemount Analytical Inc. A Division of Emerson Process Management...
Operator Interface. Power Supply Any of a variety of components that provides conditioned power to other NGA2000 components, from the Power Supply Board that plugs into the front of the Backplane in a stand-alone instrument to several larger ones that can power larger collections of modules and components.
Page 10
The five function softkeys located below the front panel display; they assume the function displayed directly above each on the display, a function dictated by software. System Any collection of Analyzer Module(s), Platform(s), I/O Module(s) and Expansion Module(s). Preface Rosemount Analytical Inc. A Division of Emerson Process Management...
Each of these I/O Modules is a self-contained A variety of analog and digital I/O Modules can communicate with chart recorders, distri- peer within the NGA2000 system. That is, it bution control systems (DCS), data acquisition has a microprocessor, memory, distinct func- systems (DAS) and other devices.
1-3 INSTALLATION AND REMOVAL 4. Tighten the two screws on the I/O Module backplate. Before installing an I/O Module, power down the network. If the I/O Module is to be in- Description and Specifictions Rosemount Analytical Inc. A Division of Emerson Process Management...
Digital Input 5 SPST Relay 1 (NC) Digital Input 6 SPST Relay 1 (C) Digital Common SPST Relay 1 (NO) Figure 1-5. Analog I/O Module Output Connector/Adapter Pin Assignments Description and Specifications Rosemount Analytical Inc. A Division of Emerson Process Management...
Standard Output ......0 to 5 VDC or 0/4 to 20 mA (isolated, software selectable) Power Requirements..... 24 VDC; 3 W maximum See Section 1 of the Platform manual for specifications regarding Platform related components. Rosemount Analytical Inc. A Division of Emerson Process Management Description and Specifications...
Page 16
Instruction Manual 748275-F Model NGA2000 I/O Modules September 2003 Description and Specifications Rosemount Analytical Inc. A Division of Emerson Process Management...
Examples of these secondary variables are flow rate and internal voltage. A software re- See Figure 2-1 for a flowchart depicting menu screens related to this I/O Module. Rosemount Analytical Inc. A Division of Emerson Process Management Analog Output/3 Alarms...
Figure 2-1. Software Displays Relative to Analog Output Line 1 status: Line 2 status: with 3 Alarms I/O Module Line 3 status: Line 4 status: Line 5 status: Line 6 status: Common range indication/control: Analog Output/3 Alarms Rosemount Analytical Inc. A Division of Emerson Process Management...
3. Select Range Change Control (Lo- cal/Auto/Remote) in the Automatic Range 6. First do the zero calibration. Set the De- Change Parameters Menu. sired Output Voltage to 0. Rosemount Analytical Inc. A Division of Emerson Process Management Analog Output/3 Alarms...
Page 20
Span Calibration Cycle Auto Calibration Timing Device Feature Auto Range Change Select *Selectable per alarm class. Table 2-1. Available Functions – Analog Output with 3 Alarms I/O Module Analog Output/3 Alarms Rosemount Analytical Inc. A Division of Emerson Process Management...
ONLY): After calibration, the output signal is then cor- rected for zero and span. (See Figure 3-1 for a flowchart depicting menu screens related to this I/O Module.) Rosemount Analytical Inc. A Division of Emerson Process Management Auto Calibration...
Figure 3-1. Software Displays Relative to Input line status Auto Calibration I/O Module Line 1 status: Line 2 status: Line 3 status: Line 4 status: Line 5 status: Line 6 status: Auto Calibration Rosemount Analytical Inc. A Division of Emerson Process Management...
The Auto Calibration Module has the fol- lowing functions: 6. First do the zero calibration. Set the De- • timed calibration sired Output Voltage to 0. Rosemount Analytical Inc. A Division of Emerson Process Management Auto Calibration...
Span Calibration on Current Range Span Calibration Cycle Auto Calibration Timing Device Feature Auto Range Change Select *Fixed in-calibration alarm. Table 3-1. Available Functions – Auto Calibration I/O Module Auto Calibration Rosemount Analytical Inc. A Division of Emerson Process Management...
NO or C) remain accurate, but pin assign- Relay 1 - span gas 1: closed when span ments relative to specific relays are different gas 1 should be flowing Rosemount Analytical Inc. A Division of Emerson Process Management System Auto Calibration I/O Module...
Auto Cal I/O Module. Do this through each Analyzer Module's menu structure. (See instruction manual for individ- ual Analyzer Module for details.) Configure System Auto Cal parameters as follows: System Auto Calibration I/O Module Rosemount Analytical Inc. A Division of Emerson Process Management...
Module Tag Range 4 upper limit: 1000 ppm (Set up ranges in the analyzer menus) Figure 4-1. Software Displays Relative to System Auto Calibration I/O Module Rosemount Analytical Inc. A Division of Emerson Process Management System Auto Calibration I/O Module...
Page 28
Span Calibration on Current Range Span Calibration Cycle Auto Calibration Timing Device Feature Auto Range Change Select Table 4-1. Available Functions – System Auto Calibration I/O Module System Auto Calibration I/O Module Rosemount Analytical Inc. A Division of Emerson Process Management...
Process Analytical Division mount Return Authorization, prepaid, to Customer Service Center the address provided by Rosemount 1-800-433-6076 CSC. Rosemount Analytical Inc. Process Analytical Division Customer Service Center 1-800-433-6076 Rosemount Analytical Inc. A Division of Emerson Process Management Return of Material...
Page 30
Instruction Manual 748275-F Model NGA2000 I/O Modules September 2003 Return of Material Rosemount Analytical Inc. A Division of Emerson Process Management...
Page 31
Instruction Sheet 748336-C Model NGA2000 I/O Module April 1997 ADDENDUM menu above allows the user to do so for cer- tain I/O-related parameters. 1-0 OVERVIEW This addendum serves as an amendment to Another important item relating to display the Input/Output (I/O) Modules instruction screens is selection in the Expert Controls manual (PN 748275).
Page 32
(select I/O Module from list), and I/O Module ID. On the right side of the screen, the default tag name will highlight (darken). The tag name can now be ed- ited. Rosemount Analytical Inc. A Division of Emerson Process Management 2 of 4 Addendum...
Page 33
3. Select Modules: Select the I/O Mod- a. Editing the System Tag: The arrow ule(s) to be bound to the selected Ana- keys are used to scroll through a re- lyzer Module. Addendum 3 of 4 Rosemount Analytical Inc. A Division of Emerson Process Management...
Page 34
<NEXT> softkey, select another At this point, all NGA 2000 system compo- Analyzer Module and repeat steps 2, 3, nents are bound and fully coordinated. and 4. Rosemount Analytical Inc. A Division of Emerson Process Management 4 of 4 Addendum...
Page 35
WARRANTY Goods and part(s) (excluding consumables) manufactured by Seller are warranted to be free from defects in workmanship and material under normal use and service for a period of twelve (12) months from the date of shipment by Seller. Consumables, glass electrodes, membranes, liquid junctions, electrolyte, o-rings, etc., are warranted to be free from defects in workmanship and material under normal use and service for a period of ninety (90) days from date of shipment by Seller.
Page 36
Instruction Manual 748275-F Model NGA2000 I/O Modules September 2003 EMERSON PROCESS MANAGEMENT EUROPEAN TECHNOLOGY CENTER Rosemount Analytical Inc. Process Analytic Division Fisher-Rosemount GmbH & Co. 1201 N. Main St. Industriestrasse 1 Orrville, OH 44667-0901 63594 Hasselroth T (330) 682-9010 Germany...