Battery Low
1. Battery monitoring enable/disable - This com-
mand enables or disables the battery low detection.
When enabled, Express II will monitor battery condition
and dial out if it becomes low. When disabled, Express
II will not dial out for a battery low condition. The
default is disabled.
2. Alarm reset time - After battery low condition is
acknowledged, Express II stops the dial out sequence.
However, the low battery condition will continue to exist
until it is recharged. If the battery is not recharged after
a certain amount of time, Express II can be pro-
grammed to restart the dial out sequence. This is
called the alarm reset time. This parameter may be
programmed from 0 seconds to 12 hours.
If the alarm reset time is programmed to 0 seconds,
the feature is disabled. Express II will not restart the
dial out regardless of how long the alarm exists.
3. Dial Out Selection - You may program Express II to
call a specific set of Phone Contacts for battery low
only. This is called the Dial out selection. To return to
the default, all contacts, press '9' '9', and then press
ENTER.
2) Enter the list of position numbers, (1-48),
for those contacts to be dialed by Express
II in the event of AC Power Failure.(Failure
monitor must be enabled. )
3) Enter list of dial out selection.
Press individual position numbers. (1-48)
Press Enter.
4) When all position numbers in list are
entered, press Enter again.
5) The default is all contacts.
Press '9' '9' for the default.

BATTERY

1) Return to the Power menu. Press 2 for
Battery Parameters.
The Battery menu will then be displayed.
> 1- Battery monitor

2- Alarm reset time

3- Dialout selectn

1-Battery monitor:

1) Press 1 for Battery monitor at the Battery
menu.
2) Press 1 to disable.
Press 2 to enable.
2-Alarm reset time:
1) Return to the Battery menu. Press 2 for
Alarm Reset Time.
2) Enter hours.
Enter minutes.
Enter seconds.

3-Dialout selection:

1) Press 3 for Dial Out Selection at the
Battery menu.
2) Enter the list of position numbers, (1-48),
for the phone contacts to be dialed by
Express II in the event of Battery
Failure.(Battery monitor must be enabled .)
Chapter 5: Programming