3.2 FRU Installation and Extraction

3.2.1 CPU Blade MIC-8301 and Peripheral Installation

The MIC-8301 supports hot-swap; it is not required to turn off the chassis power
before installing the board.

3.2.1.1 Insert/Extract CPU Blade MIC-8301

To insert MIC-8301 into the PAC-4010 chassis:
1. To ensure that the MIC-8301 will function properly in the chassis, set the SW1 &
SW2 at "off", which allows the board to function under normal mode. See
3-5
for the SW1 and SW2 Setting.
2. Following is the sequence of the handle and Health Status LED:
- Board starts to be inserted. Align the PCB edge to the card guide rail. Carefully
slide the MIC-8301 into the system until the connector contacts into the
backplane. Make sure the front panel alignment pin falls into the receptacle.
(see
Figure 3-5
- Make sure the orange latch spring is tightly locked. (see
Blue (Hot Swap LED) solid, green (Health Status LED) off
- Board inserted to the final position I:
Blue blinking (activation request to ShMC), green blinking (FW active)
- Board inserted to the final position II:
Blue off (ShMC granted activation), green blinking (FW active)
- Board inserted to the final position III:
Blue off (ShMC granted activation), green solid (ShMC allows the ATCA blade to turn
on the payload power)
3. In case of a failure, the red OOS LED (ATCA FRU LED1) will be lit.

Table 3-5: SW1 Jumper Setting

SW1 IPMC CFG
Default
__________________________________________________________________________________________
PAC-4010 User Manual V1.0
(A))
Normal operation
Copyright 2016 Advantech Co. Ltd. All rights reserved.
Figure 3-5
1 Off
2 Off
3 Off
4 Off
Table
(B))
39
Page