Page 1
User Manual EKI-1511X/1512X 1/2-port RS-422/485 Serial Device Servers...
Page 2
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ordering information.
Technical Support and Assistance Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call: –...
Page 5
Disclaimer Information in this document is subject to change without notice and does not repre- sent a commitment on the part of Advantech or any of its subsidiaries. Advantech provides this document “as is,” without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of, fitness or merchantability for a particular purpose.
2.2.4 Serial Connection................ 10 Configuration Utility Installation............... 11 Chapter Configuration ........15 Advantech EKI Device Configuration Utility overview ......16 Discovering Your Serial Device Server ........... 17 3.2.1 Auto Searching ................17 3.2.2 Cleaning the Device List and Searching Again......18 3.2.3...
Page 8
4.1.3 Manual Direct Mapping Virtual COM Port........43 4.1.4 Remove the Virtual COM Port ............ 44 Chapter Web-Based Configuration....45 Overview ....................46 Accessing the Web Page................ 46 System ....................47 Network Configuration ................48 Port Configuration ................... 48 Monitor ....................50 Auto Warning (Alarm) ................
Introduction Advantech's EKI-1511X, EKI-1512X series of Industrial Device Servers is a robust, feature-rich, and cost effective way to network-enable equipment in an industrial automation environment. EKI-1510X series provides one or two RS-422/485 serial ports. By encapsulating serial data and transporting it over Ethernet, the EKI-1510X series allows virtual serial links over Ethernet and IP (TCP/IP, UDP/IP) networks.
Software Driver Support: Windows XP/7/8/8.1, Windows Server 2008/2012/2012 R2 Utility Software: EKI Device Configuration Utility Operation Modes: COM port redirection mode (Virtual COM) TCP/UDP server mode TCP/UDP client mode Pair connection (peer to peer) mode Configuration Methods: Windows Utility, and Web Browser Mechanics ...
In this chapter, you will be given an overview of the EKI-1510X series hardware installation procedures. Understanding the Advantech EKI-1510X Series The EKI-1510X is an advanced series of device servers. They extend traditional COM ports of a PC with access over a TCP/IP network. Through networking, you can control and monitor remote serial devices either over a LAN or over the WAN.
Connecting the Hardware Next, we will explain how to find a proper location for your serial device server, and then explain how to connect to the network, hook up the power cable, and connect to the EKI-1510X series’s serial port. 2.2.1 Physical Mounting After attaching the mounting kit, you can install the EKI-1510X series serial device...
2.2.3 Power Connection Insert the power wire from DC power supply into the power contacts of the ter- minal lock connector on the EKI device. Tighten the terminal screws to prevent the DC wires coming loose. Switch on the DC power supply. If the EKI-1510X series is working properly, the green power LED will light up, indicat- ing that the EKI-1510X series is receiving power.
Configuration Utility Installation The following section will demonstrate installing the Advantech serial device server configuration utility, a tool to set up and monitor the EKI-1510 series serial device servers.: Note! Be sure that you have Microsoft .NET Framework 2.0 installed on your...
Page 20
Carefully read the Software License Agreement and press “I Agree” to continue. The setup program will install the relative files into the default path that system assigned. EKI-1511X/1512X User Manual...
Page 21
After setup program has copied all program files to your computer, click the “Fin- ish” button to finish the installation. EKI-1511X/1512X User Manual...
Advantech EKI Device Configuration Utility overview Advantech provides an easy-to-use configuration utility to configure your EKI-1510X series serial device server through an Ethernet connection. For secure administra- tion, you can lock up the devices with password. After locking with the password, only the persons who know the password can configure the password protected device.
3.2.1 Auto Searching Advantech’s EKI Device Configuration Utility will automatically search all the sup- ported devices periodically, and show on the Device List Area of the utility. The utility provides an auto-search function to show your devices by simply executing the con- figuration utility program from the Start Menu.
3.2.2 Cleaning the Device List and Searching Again You can click the button on the “Quick Toolbar”. The utility will clear all listed devices in the Device List Area and re-search again. You can click the button on the “Quick Toolbar”. The utility will search for devices again without cleaning the device list.
Setting Ethernet Parameters This section explains how to configure the device network with configuration utility. Click on the Ethernet interface node under the device node. The Ethernet configura- tion page will be shown in the Configuration Area. EKI-1511X/1512X User Manual...
Page 28
IP Address, Subnet Mask, Default Gateway: The IP address identifies your Advantech serial device server on the global network. Each EKI-1510 series has the same default IP address 10.0.0.1. Obtain these spe- cific IP addresses from your network administrator and then configure each Advan- tech serial device server with individual IP addresses, related Subnet Mask and Gateway Setting.
DNS Setting In order to use the DNS feature, you need to set the IP address of DNS server to be able to access the host with the domain name. The device provides Primary DNS server and Secondary DNS server configuration items to set the IP address of the DNS server.
The device comes with COM port redirector (virtual COM driver) that works. The driver establishes a transparent connection between host and serial device by map- ping the IP of Advantech serial device server serial port to a local COM port on the host computer.
Page 31
Host Idle Timeout (10 to 255 seconds): The “Host Idle Timeout” setting monitors the connection between the host and the device. If the “Host Idle Timeout” setting time is reached, the device server will release the resources allocated to the port mapping. This prevents a stalled host from affecting the connective device.
Page 32
Round-Robin mode: After enabling “Response Timeout” parameter, the device will operate in “Round- Robin mode”. Each serial port supports up to five simultaneous connections, so mul- tiple hosts can transmit/receive data to/from the same serial port simultaneously. Every host can transmit data to the same serial port simultaneously, but the device will process the data communication in order.
3.5.2 Data Mode (USDG Mode) The device can be Data Server or Data Client either. Both operations support TCP and UDP protocol. The device makes your serial devices behave just like networking devices. You can issue commands or transmit data from serial devices, which con- nected to the device server, to any devices that are connected to the Internet.
Page 34
Each port has its own data listen port to accept connected request of other network device. So, the data listen port can’t be set the same value. You can transmit/receive data to/from device via the data listen port. Command Listen Port Each port has its own command listen port to accept connected request of other net- work device.
Page 35
Frame Break is a very important parameter for Round Robin mode. This parameter is the smart way to reduce inefficient waiting time and the device can transmit data more efficiently. Disabling the Frame Break function, the device server will wait “Response Timeout”...
Page 36
Peer Number Set the number of network device which you want to connect. You can set a maxi- mum of sixteen network devices which you want to connect. You need to fill out the IP Address and Port of network devices which you want to connect. Data Pack Data pack means you can set condition of receiving data from serial port to be a package according to your application.
3.5.3 Control Mode (USDG Mode) In Control Mode, the EKI device presents a modem interface to the attached serial device: it accepts AT-style modem commands to connect/disconnect to other net- working device. If you want serial device running application program to connect/dis- connect to different devices dynamically, you can use controlling mode.
Dial-in (Use TCP connect to serial port of EKI) EKI listens for a TCP/IP connection request from the remote host. When a TCP con- nection is coming, there will have prompt string "RING" shows on serial port site. After the system prompting the "RING" string, user can use "ATA" command to accept the connection or just ignore it.
Advanced Settings The serial device server provides the advanced settings for some special applica- tions which need critical time requirements. In normal applications, these settings are recommended not to be set to avoid the unusual action happened. Enable Delay Time (ms) When you enable the delay time, the serial port will postpone the received data for the time interval you set, and then send the received data to the TCP/IP network.
Page 40
RTL (Receiver Trigger Level) It determines how often or when the receiver interrupt will be triggered. TTL (Transmitter Trigger Level) It determines how often or when the transmitter will be triggered. FCL (Flow Control Lower Trigger Level) FCH (Flow Control Higher Trigger Level) It determines when the transmission will be suspend or resume.
Security Configuration 3.7.1 Accessible Function Allow any IP to access: The default option, any host PC can communicate with this serial device server. Specified IP which can access: Type the IP address in the column and click “Add” or “Delete” button to make the accessible IP address list.
Port Monitor Configuration utility provides an excellent function that allows monitoring the serial ports’ status. It will present each serial port’s operation mode and status. The IP address of Host PC which is communicating with serial port will be list on the right window.
Administrator Settings The configuration utility provides several administrator settings for easy management and configuration. Right click the mouse on the device name in the sub-tree of Serial Device Sever List Area, and select these administrator settings. 3.9.1 Import/Export Device Setting The utility allows importing or exporting the serial device server’s setting via the “.conf”...
3.9.4 Lock the Serial Device Server (Password Protection) The configuration utility provides the “Lock Device” function to make it more confiden- tial. You need to set up a password while the first time clicking “Lock Device”. Be sure to click “Reset Device” to restart the serial device server and store your setting pass- word into the memory.
If you want to disable this function or change the password, click “Change Password” to change the password to default “None” (leave the new password and confirm new password columns blank) to disable this function or other password you want to change.
10 seconds, the serial device server will not have any changes. 3.9.6 Update firmware Advantech continually upgrades its firmware to keep up with the ever-expending world of computing. You can use the update firmware function in the utility to carry out the upgrade procedure. Please access Advantech’s website: http://www.advan- tech.com to download the latest version of the firmware.
Setting COM Redirector (Virtual COM port) Advantech COM port mapping software is a serial COM port redirector that creates virtual COM ports and provides access to serial devices connected to Advantech serial device servers. Your serial device applications can communicate with serial devices connected to Advantech serial device servers without software changes.
Page 49
The serial ports that can be assigned to virtual COM will be shown in this window. Select the serial ports you wish to map or click the “Select All” button and press “Map Selected Ports” button. The selected serial ports will be mapped to virtual COM ports in sequential order.
4.1.2 Manual Mapping Right click the serial device name on the sub-tree of Device Server List area and select the “Manual Mapping” function. ADAM series, EDG series, and EKI wireless series have only one IP address. Select the serial port on the device server and the host COM that you want to set. Press “Map”...
Advantech serial device server. The function "Auto Reconnect" is for this purpose, if the Advantech serial server loses the connection to its host, the COM redirector will try to re-establish the connection while the host’s AP access the virtual COM port.
4.1.4 Remove the Virtual COM Port If you want to remove the virtual COM port, you can remove them one by one or group remove ports. Individually Remove Right click on COM port you have mapped and select “Remove This Port”. Group Remove Port ...
Overview The EKI-1510X series serial device server can be configured through a web inter- face. By using a standard web browser, the same procedure as with the Windows configuration utility can be used. In the browser’s address field, enter the IP Address of your EKI-1510X series serial device server.
System You can change the Device Name and Device Description on this page. You can also enable or disable the Web, Telnet, and SNMP functions. You can also set the Time zone related setting. EKI-1511X/1512X User Manual...
Network Configuration Click the Net Configuration, there are Net Mode, IP Address, Subnet Mask, Default Gateway and DNS. Enter the corresponding values for your network environment. Remember press “Save” after fill in all values. Port Configuration There are Basic, Operation Mode, and Advanced Setting in the serial port configura- tion.
Auto Warning (Alarm) You can set the e-mail server and SNMP Trap server in the Setting page, and set the event type in the Event page. EKI-1511X/1512X User Manual...
Change Password You can change the serial device server password on here: If you want to disable the password protection, just change the password to the default “None” (leave the new password column blank), Be sure to press the “Save” button and reboot the serial device server to make the change effective.
5.10 Reboot The configuration will take effect after clicking “Save” button. But all configurations will save to flash memory after this reboot step. Press the “Reboot” button and the system will give a reset response. It will take a few seconds to reconnect with the new values.
Overview The purpose of the Console Configuration is to help you manage your device in con- sole mode. One of the main functions of the console mode is to change the web con- figuration login password. You can use terminal software like Hyper Terminal, Telix and other related terminal software.
Page 67
System Manage the general information about the device. [Usage] system [Function] Show firmware version, device name and description [Usage] system [Function] Show current device status and information [Usage] system name XXXX [Function] Set current device name [XXXX: maximum length 31 bytes] [Usage] system desc XXXX [Function] Set current device description [XXXX: maximum length 127 bytes] ...
Page 68
mvcom Show and setup the VCOM mode [Usage] mvcom [Function] Show all serial ports mode and related information [Usage] mvcom nn|all [Function] Set the “nn”th or all serial ports as the Virtual COM mode [Usage] mvcom nn|all idleto XX [Function] Set the “nn”th or all serial ports host idle timeout (S) [Usage] mvcom nn|all respto XX framebk XX [Function] Set the “nn”th or all serial ports response timeout and frame break...
Page 69
[Usage] mdata nn|all peernum 1|2|3|4|5|6|7|8|9|10|11|12|13|14|15|16 peer XX.XX.XX.XX:ppp [Function] Set the peer IP address and port for receive data Show and setup the Ethernet port configuration [Usage] net 1|2 [Function] Show the first or second Ethernet port status and information [Usage] net 1|2 mode static|dhcp|boot|all [Function] Set the network operating mode [Usage] net 1|2 ip XX.XX.XX.XX netmask XX.XX.XX.XX gw XX.XX.XX.XX...
Page 70
import/export Import or export the device setting. [Usage] import [Function] Import the serial device server settings’ file [Usage] export [Function] Export the serial device server settings’ file monitor Show the serial ports settings, statistic, and connected IP address [Usage] monitor port 1|2|…|16 setting [Function] Monitor the serial ports settings [Usage] monitor port 1|2|…|16 statistic...
Page 71
time Show or configure the time information [Usage] time [Function] Show the current time information [Usage] time YYYYMMDDhhmmss [Function] Modify the current time information [Usage] time timezone -12|…|0|1|…|12 [Function] Set the current timezone configuration [Usage] time daylight on|off begin MMDD end MMDD [Function] Set the current time daylight saving configuration [Usage] time ntp XXXX [Function] Set the NTP timeserver [XXXX: time server]...