1.2.2

Flush mounting (optional)

You can use the optional FM FIXTURE ASSEMBLY kit (OP24-38) to flush-mount the
unit.
Note: The flush mount location must have a thickness of at least 10 mm, with a max-
imum thickness of 20 mm.
1. Referring the outline drawing at the back of the manual, mark and cut a hole in the
position you wish to locate the unit.
2. Set the USB cable through the hole, then place the unit inside the hole.
3. Attach two FM (flush mount) fixture assembly to the unit's under side using four
washer head screws (M410), both included in the kit.
4. Fasten the wingbolts until the footing is flush against the mounting area.
Footings are flush against
the mounting area
5. Tighten the wingnuts until the unit is firmly secured.
Type: OP24-38, Code No.: 001-263-190
Name
FM Fixture Assembly
Washer Head Screw
Console (Underside)
Wingnut
Wingbolt
Type
Qty
OP24-38-1
2
M410
4
FM fixture assembly
1. MOUNTING
1-9