How To Attach Ferrule-Type Lug; Sensor Adapters (Optional) - Furuno FMD3100 Installation Manual

Hide thumbs Also See for FMD3100:
Table of Contents

Advertisement

2.2

Sensor Adapters (Optional)

Maximum eight MC-3000S can be connected to a sensor network (for the redundant
connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect
max. 10 sensor adapters using the MC1.5-W cables.
To connect the lines to the connector on the sensor adapter, use the rod terminal (fer-
rule type, supplied) to maintain performance. This fabrication requires the optional
crimping tool (type: CRIMPFOX 10S).

How to attach ferrule-type lug

Vinyl sheath
Rod terminal (ferrule type):
After attaching the rod terminal, use the optional
crimping tool CRIMPFOX 10S to crimp.
For the relations between the connectors and rod terminals, see page AP-2. Also, the
stickers attached on the reverse side of the covers show the detailed connections.
Use the MC1.5-W cable between the sensor adapters. Attach the cables to the appli-
cable pins.
Pin No.
1
2
3
4
5
Note: The total length of the MC1.5-W cables should be less than 6 m to prevent mal-
function.
L
Core
0.5 to 1 mm
Cable color
Red
24V_OUT or 24V_IN
Black
24V_GND
White
MODBUS-A
Blue
MODBUS-B
Gray
GND
Ferrule-type lug
AI 1.5-6 BK (BLK)
AI 0.34-6 TQ (BLU)
AI 0.75-6 GY (GREY)
AI 1-6 RD (RED)
AI 0.14-8 GY(GREY)
Rod terminal (ferrule type):
The core must protrude 0.5 to 1 mm
past the rod terminal.
Signal
2. WIRING
Length of "L"
6 mm
8 mm
2-11