5. Place the cap strap, then tighten the nut to secure the cable. See the figure below.
Note: Always screw the cap on when the extension cable is not in use.
2.1.3
Fabricating the power cables
When using AC power, connect the unit with the supplied AC power cables. If the
power supply is DC, fabricate DPYC-1.5 cables as shown below. Wago connectors
must also be fitted.
For cable clamp location when using DPCY-1.5 cables, see paragraph 2.1.6.
Cable jacket
Wrap with vinyl tape (width: 20 mm)
WAGO
connector
screw
Wire
<Procedure>
1. Twist the core wire.
2. Unfasten the WAGO connector screw.
3. Insert the core wire into the connector.
4. Fasten the WAGO connector screw.
5. Make sure the wire does not come loose.
Installation point - console, etc.
Sheath
80
* For flush mounted installation, the length of stripping
should be based on the installation location.
WAGO connection
Twist
6
150
*
WAGO connection port
2. WIRING
USB3
USB4
LAN2
2-5