Scx-21 Settings; Optional Equipment - Furuno FR-10 Operator's Manual

Marine radar
Table of Contents

Advertisement

1. INSTALLATION & WIRING
1.4.8

SCX-21 settings

The items described in this section assume that your FR-10/12 is connected with an
SCX-21 on the same network. If a SCX-21 is not connected, the menu items cannot
be changed. For detailed instructions on these settings, see the operator's manual for
the SCX-21.
• [Datum]: Select the datum to use for SCX-21 positioning. The default setting is
[WGS84]. To manually select a datum other than [WGS84] or [WGS72], select [Oth-
er].
• [Datum Number]: Set the datum for the SCX-21 to use for positioning. This menu
item is only available when [Datum] is set to [Other].
• [SBAS Mode]: Set to [On] to use the SCX-21 for SBAS (Satellite Based Augmen-
tation System). Set to [Off] to ignore SCX-21's SBAS.
• [Offset HDG]: Apply an offset to the heading data received from the SCX-21.
• [Offset Pitch]: Apply an offset to the pitch data received from the SCX-21.
• [Offset Roll]: Apply an offset to the roll data received from the SCX-21.
• [Smoothing SOG/COG]: Apply time-based "buffer" to SOG/COG data received
from the SCX-21.
• [Smoothing ROT]: Apply time-based "buffer" to ROT data received from the SCX-
21.
• [Port1 Setting]: Set the load rate and baudrate for output sentences from the SCX-
21's Port1.
• [Port2 Setting]: Set the load rate and baudrate for output sentences from the SCX-
21's Port2.
• [Port3 Setting]: Set the load rate and baudrate for output sentences from the SCX-
21's Port3.
• [Factory Reset]: Restore the SCX-21 to factory default settings.
1.5

Optional Equipment

External buzzer
The external buzzer alerts you when targets violate the guard zone set. Connect the
buzzer to the display unit as shown below, using the external buzzer installation kit.
External Buzzer Installation Kit
Type: OP03-21, Code No.: 000-030-097
Name
1
Buzzer
2
Cable Tie
3
Heat Shrink Tube
4
Double-sided Tape
1-18
Type
PKB42SWH2940
000-153-221-10
CV-70N
000-162-185-10
3×0.25 BLK
25×25×T0.91MM
000-173-188-10
Code No.
Qty
1
5
1
1
Remarks
Connector at both ends
25 m×25 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-12

Table of Contents