How To Set Ack Input (Mc-3020D); Input Circuit For Voltage Input; Input Circuit For Contact Input; Connector J3 - Furuno FMD3100 Installation Manual

Hide thumbs Also See for FMD3100:
Table of Contents

Advertisement

How to set ACK input (MC-3020D)

Use the connectors J3 to J6 on the MC-DIN Board (24P0116) to set the ACK input for
ACK1 to ACK8 as shown below.

• Input circuit for voltage input

DC voltage input
(21.6V to 31.2V)

• Input circuit for contact input

Use NH connector
and AWG24 wire.
Contact input
Note: The input must not exceed the range of the input voltage, to prevent
malfunction.
-Setting for voltage input: 21.6 V to 31.2 V
-Setting for contact input: Voltage cannot be input (contact signal only).
Pin
Signal name
#
1
DC12V_OUT
2
DIGI_IN1
3
DIGI_RTN1
4
GND (DC12V) In
5
DC12V_OUT
6
DIGI_IN2
7
DIGI_RTN2
8
GND (DC12V) In
470Ω/ 0.5W
DC12V_OUT
+
DIGI_IN1
DIGI_RTN1
-
GND(DC12V)
470Ω/ 0.5W
DC12V_OUT
DIGI_IN1
DIGI_RTN1
GND(DC12V)

Connector J3

In/
ACK1
Remarks
Out
contact
Out
Pin #1-#2:
short
In
ACK1 In
Out
MPYC-12
Out
In
ACK2 In
Depending on ACK2 input
Out
12V
5V
2.2kΩ / 1W
GND
Photocoupler circuit
GND
12V
5V
2.2kΩ / 1W
GND
Photocoupler circuit
GND
ACK voltage
No connection
MPYC-12
Depending on ACK1 input
No connection
Pin #1-#2:
short
MPYC-12
2. WIRING
Register
To internal
circuits
Register
To internal
circuits
ACK2
ACK2
contact
voltage
No connec-
tion
MPYC-12
No connec-
tion
2-21