2. WIRING
How to connect the JIS cables to the WAGO connectors
WAGO connectionfor IEC161162-1 lines
WAGO connector screw
Wire
<Procedure>
1. Twist the core wire.
2. Unfasten the WAGO connector screw.
3. Insert the core wire into the connector.
4. Fasten the WAGO connector screw.
5. Make sure the wire does not come loose.
How to attach the EMI ferrite core
Attach the EMI ferrite core (supplied) to each connected cable group, as close to the
WAGO connector as possible, leaving the drain wire loose (See figure below).
2-8
Twist
EMI ferrite
core
WAGO connectionfor IEC161162-2 lines
WAGO connector screw
Wire
<Procedure>
1. Twist the core wire.
2. Unfasten the WAGO connector screw.
3. Insert the core wire with the resistor into
the connectors P4 & P5.
4. Fasten the WAGO connector screw.
5. Make sure the wire does not come loose.
EMI core attached
to serial cable
Drain wire left loose
P4 & P5
Resistor