Select [Password] for the Data Type in the attributes page of [Numeric Data], as follows:
The process is the same for changing other system parameters online. But note that after changing the
following system parameters, the HMI needs to be rebooted to validate the changes.
System Parameter Setting: the following addresses will take effect after reboot.
Addresses
10010
10011
10013
10014
10015
10016
10017
10018
NB-series Programmable Terminals Startup Guide Manual(V109)
Descriptions
Initial Window number
Screen saver (backlight saver)
Common window/Pop-up window
Common window/attribute
Storage event number
RTC source
Default language
System reserve
6 Maintenance and Troubleshooting
comments
0~65535
0 (OFF, Constant, Screen saver inactivated)
1~600 minutes (activated)
0: Normal
1: Higher than other windows
0: Lower than the Base window
1: Higher than the Base window
0~65535
0: PLC(Local Word)
1: Internal RTC
0~3
HMI internal use
6
6-7