Basic Commands - Bentel Security KYO 320 User Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Basic Commands

You can con trol eight ba sic com mands from standby
sta tus by typing-in your code and pres sing the re spec ti -
ve keys (re fer to the fol lo wing Ta ble). Access to ALL
com mands — ex cept 'View Tro u ble' — re qui re entry a
va lid User Code PIN.
Keypad set normally
Enter
<Code> ON
<Code> OFF
<Code> A
<Code> B
<Code> C
<Code> D
<Code> ENTER
ONLY ENTER
List "By-passed zones"/"By-
ONLY ESC
Keypad set as EN50131
Key sequence (from
standby status)
<Code> ON
<Code> OFF
Message
Tr oub. _pow. s y s t .
Low_bat t er y
AC_M ai ns _f ai l ur e The Mains pow er to the Control panel or to at least one Pow er station has failed
Bat t . _di s c . pw. s .
Faul t _c hr g. pw. s .
Swt c h. di s c . pw. s .
Out _s hor t __pw. s .
Tel . _l i ne_t r oub.
Fus e_B1
Fus e_B2
Fus e_B3
Fus e_B4
Fus e_B5
Fus e_+F
Fus e_BPI _1
Fus e_BPI _2
Fus e_KEYBUS
St op_al . j um p. i n
Low_bat t er y _W LS
W ar n. l i t hi um bat t
Cal l I ns t al l er
Cal l Cent r . St at .
Day l i ght Sav i ng
W LS Dev i c e l os t
Cl oc k St opped
Vox _boar d_l os t
St ar t _pr ogr am .
I nac t i v i t y
Di s c l os ed PI N
8
COMMAND
Arm
Disarm
A Mode Arm
B Mode Arm
C Mode Arm
D Mode Arm
Access User Menu
"View trouble" mode
passed zone"
COMMAND
Arm
Disarm
TABLE 5 - "VIEW TROUBLE" MODE
The Control panel battery or at least one Power Station is not functioning properly
The Control panel battery or at least one Power Station battery is low
At least one Pow er Station has disconnected its Battery
At least one Pow er Station has Battery-charger trouble
At least one Pow er Station has disconnected its Battery-charger
At least one Pow er Station has one Output in short-circuit
Line down
Shortcuts/blown fuse on terminals +N1 and +A1 (1.85A-250V)
Shortcuts/blown fuse on terminals +N2 and +A2 (1.85A-250V) KYO320 only
Shortcuts/blown fuse on terminals +N3 and +A3 (1.85A-250V) KYO320 only
Shortcuts/blown fuse on terminals +B4 (1.85A-250V) KYO320 only
Shortcuts/blown fuse on terminals +B5 (1.85A-250V) KYO320 only
Shortcuts/blown fuse on the power line +F (1.85A-250V)
Shortcuts/blown fuse on BPI line1 (1.85A-250V)
Shortcuts/blown fuse on BPI line2 (1.85A-250V)
Shortcuts/blown fuse on the Key Bus (500 mA-250V)
STOP ALARM jumper is connected
Low Battery on one or more Wireless devices
The RAM battery must be replaced
Service is due — Call your Installer
Central Station intervention is due — Call your Central Station
The Control panel Clock has been turned forward/back
Connection problems with a Wireless device (Missing or Trouble present)
The Control panel Clock has stopped
Connection problems with the Vox Board (Missing or Trouble)
Programming session via PC (on-site or via Modem) started during Disarmed status
The zone"Inactivity Time" has expired
A PIN (DUPLICATED at random) has been DISCLOSED to another User
<Code> A
<Code> B
<Code> C
<Code> D
View Area status if there are no
malfunctions, otherwise View
<Code> ENTER
From the View area status or
malfunctions screen, press
ENTER again to access the
+
'View Tro u ble' mode is ava i la ble on LCD Key pads
at all ti mes, and can be ac ces sed wit ho ut en te ring
a Code.
+
Com mands will af fect only the Par ti tions com mon
to both the User code and Key pad con cer ned
(com mon Par ti tions).
Inva lid com mands will be si gnal led by a buzz and the
fol lo wing mes sa ge:
17:05 26/08/2005
Invalid code!
in va lid com mands may be due to the User code or the
Key pad (e.g. the User code is Di sa bled on the Key pad
Par ti tions).
Description
A Mode Arm
B Mode Arm
C Mode Arm
D Mode Arm
malfunctions.
User menu.
KYO320