Setting the handwheel scale

6
Proper setting
1. Lock the machine in place at position 2 ( p. 24).
 The handwheel is at position 0°.
Cover
• Remove the arm cover ( p. 15)
• Remove the front cover ( p. 18)
• Remove the belt cover ( p. 20)
Fig. 20: Setting the handwheel scale (1)
(1) - Handwheel flange
(2) - Toothed belt wheel
To set the handwheel scale:
1. Place the handwheel flange (1) on the shaft.
 The handwheel flange (1) abuts on the toothed belt wheel (2).
2. Loosen the screws (3).
Service Instructions 1767 - 00.0 - 12/2016
Setting the handwheel scale
CAUTION
Risk of injury from moving parts!
Crushing possible.
Switch off the machine before you check and set
the position of the handwheel on the arm shaft.
If a different degree number is next to the marking (2) then you will
have to reset the graduated scale.
(3) - Screws
(4) - Screws