THE SLIDE OWNER MUST REVIEW THE MANUFACTURER'S PLACEMENT INSTRUCTIONS WITH
THE INSTALLER TO ENSURE THAT THE MANUFACTURER'S INSTALLATION REQUIREMENTS
HAVE BEEN MET.
PROPER ASSEMBLY, INSTALLATION, USE AND SUPERVISION IS ESSENTIAL FOR PROPER
OPERATION AND TO REDUCE THE RISK OF SERIOUS INJURY OR DEATH.
1. The critical dimensions for placement of the heliX
A. The slide exit runway surface shall not exceed 20" (508 mm) above the water surface as shown
in FIGURE 2.
B. The slide shall be positioned so that all water flowing off the runway exit drops into the pool.
Recommended overhang is 4" (102 mm).
C. The minimum depth of water below the exit lip of the slide shall be 3' (914 mm) and increases to
4'-6" (1372 mm) at Pt. A, which is a distance of 4'-6" (1372 mm) from the exit lip of the slide as
shown in FIGURE 2.
D.
A minimum depth of 4'-6" (1372 mm) shall be maintained at a distance of 9' (2743 mm) along the
extended centerline of the slide from Pt. A. as shown in FIGURE 2.
FIGURE 2
RUNWAY SURFACE
20" MAX.
(508mm)
WATER LEVEL
(1372mm)
4'-6" MIN.
9' MIN.
(2743mm)
13'-6" MIN.
Dimensions are in feet/inches and (millimeters)
2. A minimum clearance area in front of the slide shall be maintained at all
times as follows:
The minimum clearance distance on either side of the extended centerline of
the slide runway shall not be less than 3'-6" (1067 mm) at a point no less than
2'-6" (762 mm) from the exit lip of the slide and extending a distance of 13'-6"
(4115 mm) in front of the slide as shown in FIGURE 3.
EXIT
3' MIN.
4'-6" MIN.
(914mm)
Pt.A
4'-6"
(4115mm)
TM
are as shown in FIGURES 2 and 3.
PLUMBLINE