Programming Options
CODE PARAMETER
Data type
Baud rate
Data bits*
Parity*
Stop bits*
Xon/Xoff handshaking
Predefined serial defaults
Protocol
Timeout
*The PowerWedge 10 will not operate with a combination of 7 data bits, no parity, and 1 stop bit
10-millisecond increments; the default setting (01) means 10 milliseconds
45
Table 7
I.D.
ACCEPTABLE
TYPE
#
INPUT
C0
Value
50 = ASCII
51 = PC scan codes
C1
Value
00 = 300
01 = 600
02 = 1200
03 = 2400
04 = 4800
05 = 9600
06 = 19200
07 = 38400
08 = 57600
C2
Value
07 = 7 Bits
08 = 8 Bits
C3
Value
00 = None
01 = Mark
02 = Space
03 = Odd
04 = Even
C4
Value
01 = 1 Bit
02 = 2 Bits
C5
On/
On or Off
Off
C8
CA
Value
00 = EOR only
01 = ACK/NAK
CD
Value
00 = 2.55 seconds
PREDEFINED
DEFAULT (C8)
Enter 1 for On and 0 for Off.
00–99
PowerWedge
50
05
08
00
01
Off
00
01
®
10