Programming the PowerWedge 10
Figure 7. On-screen programming options for Codabar, Ames, MSI, and Code 93
NOTE
21
CODABAR/Ames
0 ENABLE=1
1 MIN LENGTH=04
2 MAX LENGTH=20
3 TRANSMIT START/STOP=0
4 CODABAR TO CLSI CONVERSION=0
5 INTERCHARACTER GAP CHECK=0
MSI
6 ENABLE=0
7 MIN LENGTH=04
8 MAX LENGTH=10
9 2ND CHECKSUM REQUIRED=0
A 2ND CHECKSUM MOD 11=0
B TRANSMIT CHECKSUM=0
CODE93
C ENABLE=1
D MIN LENGTH=02
E MAX LENGTH=20
(0-B):
Notice that the parameters in this list are also identified by numbers
and letters. The value following the equals sign (=) in each line is the
current setting for that parameter (0 means off, and 1 means on).
The last line is the input prompt.
To return to the previous menu level, press the
board.
5. Type the I.D. of the parameter whose setting you want to change,
and press
. A prompt will display the valid settings or range of
Enter
settings for the parameter, as shown in the following example:
ENABLE CODABAR/AMES (0¦1):
6. Type the setting you want to use, and press
will be redisplayed to verify the change you made.
key on your key-
Backspace
. The list of options
Enter
PowerWedge
®