STL FB 10
:
:L
FW 228
:L
FW 128
:! = F
:BEC
:L
FW 128
:T
FW 228
:L
FY 128
:T
PY 128
:L
FY 129
:T
PY 129
:BE
6.7.8
Transferring the Parameter Setting Data (Job Number 90
You can transfer data for a parameter block to the CP 523 with a "Transfer parameter setting
data" request:
Data for the serial interface (corresponds to parameter block 0 on the memory submodule)
Characters for XON/XOFF protocol (corresponds to parameter block 2 on the memory
submodule)
Setting the mode and the parameters (corresponds to parameter block 7 on the memory
submodule)
Note:
"Transfer parameter setting data" job is almost without significance in Print mode since the
parameter setting data for Print mode are stored in DB 1 on the memory submodule.
A typical application might be if you want to replace a defective printer temporarily with
another printer whose interface has been configured differently.
The job does not change the contents of the memory submodule plugged into the CP 523.
After a warm restart, the CP continues to use the data on the memory submodule.
See 7.3.2 for a detailed description.
6-48