Parameter data record

B.1
Parameter defaults and dependencies when configuring with
GSD file
When configuring the module with a GSD file, remember that the setting of some parameters
are dependent on each other.
F-TM Count module and encoder
The following are F-TM Count module default parameters:
Channel activation
Enabled
The following are encoder default parameters:
Signal type
Sin/Cos
The following are F-TM Count default parameters using STEP 7 or GSD:
STEP 7
GSD
Parameter errors result whenever "Low Limit" >= "High Limit", "High Limit" < "Start Value", or "Start
1
Value" < "Low Limit".
Signed values are not supported using FCT V2.0. Negative values must be entered as their equiva-
2
lent two's compliment values (for example, 2147483648 = - 2147483648 and 4294967295 = -1).
Measured value
The following are measured value default parameters:
Measured value
Frequency
Period
Velocity
ET 200SP F-TM Count 1x1Vpp sin/cos HF (6ES7136-6CB00-0CA0)
Equipment Manual, V1.0, 01/2021, A5E47073911-AA
Count/Pos input
Enabled
Invert direction
Pulses per revolu-
tion
Disabled
1024
High limit
Start
Low limit
value
2147483647
0
-2147483648
2147483647
0
0
1
1
Update time
100
100
100
Measuring
Enabled
Signal evaluation
Quadruple
Counting
violation
Continue
,
Continue
1
2
Time base (velocity)
0
0
0
B
Signal monitoring
Enabled
Reaction to
N signal
No reaction
Reset
Reaction
upon
to Gate
violation
start
Start value Set to start
Start value Set to start
Counts/Unit (velocity)
1
1
1
87