Direct entry with the "KH" format
The control parameters are entered direct with the "KH" format during configuration of a
message text.
You must use the table to find the ASCII codes of the control parameters. Switch from the "KS" or
"C" format to the "KH" format on the programmer and specify the control parameters in
ASCII code. Then switch back to the "KS" or "C" data format.
Note:
If you use the "Print all configured message texts" job 8000
control parameters have been entered direct, these control parameters will be executed and will
not appear as configured.
Example:
Configuring a message text with a place holder for control parameters
(direct entry).
You want to store the following message text in DB 4:
Message text 40: Motor works <Line feed> <Carriage return> Newhaven <Line feed>
<Carriage return> 9999 Wackeldorf
Input at the PG 685 for DB 4
:
KS = '40:Engine Plant';
:
KH = 0A0D
:
S = 'Newhaven';
:
KH = 0A0D
:
KS = '9999 Wackeldorf$';
:
6-22
to print message texts in which
H
Explanation
Message text no. 40, separator ":",
message text
ASCII code for line feed (0A
carriage return (0D
)
H
Message text
ASCII code for line feed (0A
carriage return (0D
)
H
Message text, end-of-message character
CP 523
) and
H
) and
H