Installation

General
When the appliance is not fitted with a power
cord with plug, the appliance may only be
connected by a qualified electician.
Please note:
The correct voltage for the appliance and the
connection value are shown on the rating plate
at the back of the oven. Always comply with
local regulations when connecting the
appliance.
U.K. only
To connect the appliance a fixed connection has
to be made. The wire which is coloured green
and yellow must be connected to the terminal
which is marked by the letter E or the earth
symbol
or which is coloured green, or green
and yellow. The wire which is coloured blue
must be connected to the terminal which is
marked by the letter N or which is coloured
black. The wire which is coloured brown must be
connected to the terminal which is marked by
the letter L or which is coloured red. If the input
of the appliance acceeds 3 kW, the appliance
has to be connected to an outlet with a rated
current exceeding 13 Amp.
Electrical connection
230 V - 50 Hz.
Make sure the appliance has an earth wire
connection. Use good quality cable for
connecting, e.g. H05RRF, 1,5 or 2,5 mm
or 5 cores, depending upon the regulations.
With following colour code:
brown =
blue =
green/yellow =
earth (
black =
neutral or phase
Depending upon the wiring diagram, you can
use the black cores for neutral or a phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
Wiring diagrams
There is a label showing the wiring diagrams
on the underside of the appliance.
Supply terminals
The supply terminals are accessible by
removing the cover plate on the underside.
You can make the cross connections needed
using the jumpers on the terminal block.
Do not forget to secure the cable with the
cable clamp. Refit the cover plate after you
have secured the cable.