Non-Hot-Plug Drive - HP ProLiant ML150 Gen9 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML150 Gen9:
Table of Contents

Advertisement

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
Back up all server data on the drive.
1.
Unlock and remove the tower bezel
2.
Determine the status of the drive from the Hot-plug drive LED definitions (on page 76).
3.
Remove the drive.
4.
To replace the component, reverse the removal procedure.

Non-hot-plug drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
Back up all server data on the drive.
1.
Unlock and remove the tower bezel
2.
Power down the server (on page 23).
3.
Remove all power:
4.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on its side.
5.
Remove the access panel (on page 24).
6.
If installed, remove the PCI air baffle (on page 25).
7.
Remove the system air baffle (on page 24).
8.
Remove the fans (on page 25).
9.
Disconnect the drive cables from the rear of the drives.
10.
Remove the non-hot-plug drive cage from the server:
11.
("Remove the tower
bezel" on page 23).
("Remove the tower
bezel" on page 23).
Removal and replacement procedures 28